30-ID-B,C: HERIX & NRS
XSD
GeoScience, Life Sciences, Materials Science, Physics
GeoScience, Life Sciences, Materials Science, Physics
This beamline mainly offers momentum-resolved inelastic x-ray scattering with high resolution (HERIX, about 1.5 meV). Also, limited time is offered for nuclear resonant scattering (NRS) for Sn-119 isotope. Sector 30-ID is operated by the IXN group within XSD.
Beamline Specifications
Source Upstream : Undulator 1.35cm - 2.4m or 2.1m length
Source Downstream : Undulator 1.35cm - 2.4m or 2.1m length
Monochromator Type : Cryo-cooled Si(111)
Energy Range : 23.7-23.9 keV
Resolution : 1 x 10-4
Flux : 2 x 1013 @23.7 keV
Source Upstream : Undulator 1.35cm - 2.4m or 2.1m length
Source Downstream : Undulator 1.35cm - 2.4m or 2.1m length
Monochromator Type : Six-bounce Si HRM
Energy Range : 23.7-23.9 keV
Resolution : 4 x 10-8
Flux : 6 x 109 @23.7 keV
Beam Size Hxv :
Focused : 35µm x 15µm
Source Downstream : Undulator 1.35cm - 2.4m or 2.1m length
Monochromator Type : Cryo-cooled Si(111)
Energy Range : 23.7-23.9 keV
Resolution : 1 x 10-4
Flux : 2 x 1013 @23.7 keV
Source Upstream : Undulator 1.35cm - 2.4m or 2.1m length
Source Downstream : Undulator 1.35cm - 2.4m or 2.1m length
Monochromator Type : Six-bounce Si HRM
Energy Range : 23.7-23.9 keV
Resolution : 4 x 10-8
Flux : 6 x 109 @23.7 keV
Beam Size Hxv :
Focused : 35µm x 15µm
Quick Stats
Current Status
Operational/Accepting General Users
Operational/Accepting General Users
Access Mode
On-site
On-site
Special Capabilities
The incident bandpass for HERIX and NRIXS spectrometer is 1 meV.
The incident bandpass for HERIX and NRIXS spectrometer is 1 meV.
Beamline Contacts
Beamline Techniques
Inelastic x-ray scattering (1 meV resolution)
Nuclear resonant scattering
Endstations
30-ID-C: HERIX
Non-resonant, momentum-resolved inelastic x-ray scattering experiments.
Non-resonant, momentum-resolved inelastic x-ray scattering experiments.
30-ID-C: HERIX
Total resolution 1.5 meV, ideal for phonon measurements.
Total resolution 1.5 meV, ideal for phonon measurements.
30-ID-B: NRS
Nuclear resonant scattering for Tin isotope (119Sn)
Nuclear resonant scattering for Tin isotope (119Sn)
30-ID-B: NRS
Synchrotron Moessbauer spectroscopy with about 10 neV resolution (SMS).
Synchrotron Moessbauer spectroscopy with about 10 neV resolution (SMS).
Detectors
CdTe Pilatus3 Area Detector
Avalanche PhotoDiodes (APDs)
PIN diode
Ionization chambers
Perkin Elmer area detector (20cm x 20 cm)
Equipment
high-pressure, low (5 K) temperature cryostat
high temperature furnace (~800 K)
in-line ruby pressure measurement system
Diamond anvil cells (DAC's)
ARS He Displex (10-800 K)
Sample magnet (1.2T and 2.2T)
Uniaxial strain cell
Additional Information
Additional Information
https://www.aps.anl.gov/Sector-30
https://www.aps.anl.gov/Sector-30
Software
EPICS, SPEC
EPICS, SPEC
Beamline Controls and Data Acquisition
EPICS, SPEC
EPICS, SPEC