1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Lambda EMS mismatch errors
From: Anthony Andrews <[email protected]>
To: [email protected]
Cc: Yujong Kim <[email protected]>
Date: Tue, 23 Oct 2012 18:17:50 -0600
Hi All,

My name is Anthony (Tony) Andrews and I'm a graduate student at Idaho State University. 

We are working on a control system for a Lambda EMS power supply with an RSTL controller. 

The setup for this system is: 

Computer -> TCP/IP -> MOXA Terminal Server (RS485 to RS232 interface) -> Lambda EMS power supply (RS232 in RSTL)

We were able to communicate to the power supply using telnet. 

However, we are getting several mismatch type errors where the current is expected but instead you see the voltage and vice versa. 

I used an @mismatch exception handler for the measurement of the current (MC) and measurement of the voltage (MV) protocols.  But, it only fixes it once and we run back into mismatch errors! 

In this email, I attached my protocol and database files for your reference. 

I get this when I run the IOC where I changed the IP address here to xxx.yyy.zzz.aaa and 4008 is the 8th port in the Terminal Server. 

tony[251]# ./st.cmd
#!../../bin/linux-x86/EMS
## You may have to change EMS to something else
## everywhere it appears in this file
##############################################################################
# Set up the environment
< envPaths
epicsEnvSet("ARCH","linux-x86")
epicsEnvSet("IOC","iocEMS")
epicsEnvSet("TOP","/home/tony/Power_Supplies/Lambda_EMS")
epicsEnvSet("SNCSEQ","/usr/local/epics/extensions/src/synApps_5_5/support/seq-2-1-10")
epicsEnvSet("ASYN","/usr/local/epics/extensions/src/synApps_5_5/support/asyn-4-20")
epicsEnvSet("STREAM","/usr/local/epics/extensions/src/synApps_5_5/support/stream-2-4-1")
epicsEnvSet("EPICS_BASE","/usr/local/epics/base-3.14.12.2")
epicsEnvSet "STREAM_PROTOCOL_PATH" "/home/tony/Power_Supplies/Lambda_EMS/db"
#############################################################################
# Allow PV name prefixes and serial port name to be set from the environment
epicsEnvSet "P" "LamEMS"
#epicsEnvSet "R" "$(R=TEST)"
# The environmental variables below are for the terminal server. 
# Each TCP represents a port in the back of the terminal server.
epicsEnvSet "TCP8" "134.50.87.130:4008"
#############################################################################
cd /home/tony/Power_Supplies/Lambda_EMS
## Register all support components
dbLoadDatabase "dbd/EMS.dbd"
EMS_registerRecordDeviceDriver pdbbase
#############################################################################
# Set up ASYN ports
#drvAsynIPPortConfigure("portName","hostInfo",priority,noAutoConnect,noProcessEos)
drvAsynIPPortConfigure("P8","xxx.yyy.zzz.aaa:4008",0,0,0)
asynSetTraceIOMask("P8",-1,0x2)
asynSetTraceMask("P8",-1,0x9)
############################################################################
## Load record instances
#dbLoadRecords("db/xxx.db","user=tonyHost")
dbLoadRecords("db/EMS_01.vdb","P=LamEMS,PORT=P8,A=1")
#dbLoadRecords("db/asynRecord.db","P=$(P),R=asyn,PORT=P8,ADDR=1,OMAX=0,IMAX=0")
###########################################################################
# Start EPICS
cd /home/tony/Power_Supplies/Lambda_EMS/iocBoot/iocEMS
iocInit
Starting iocInit
############################################################################
## EPICS R3.14.12.2 $Date: Mon 2011-12-12 14:09:32 -0600$
## EPICS Base built Oct 17 2012
############################################################################
2012/10/23 18:05:13.424 xxx.yyy.zzz.aaa:4008 write 2
SR
2012/10/23 18:05:13.424 xxx.yyy.zzz.aaa:4008 write 9
PV20.000\n
iocRun: All initialization complete
###########################################################################
## Start any sequence programs
#seq sncxxx,"user=tonyHost"
epics> 2012/10/23 18:05:13.924 xxx.yyy.zzz.aaa:4008 write 3
MC\n
2012/10/23 18:05:13.936 xxx.yyy.zzz.aaa:4008 read 5
MC\n\r\000
2012/10/23 18:05:13.936 P8 LamEMS:ADDR:CURR_M: Input "MC" mismatch after 0 bytes
2012/10/23 18:05:13.936 P8 LamEMS:ADDR:CURR_M: got "MC" where "Current = " was expected
2012/10/23 18:05:13.936 xxx.yyy.zzz.aaa:4008 write 3
MV\n
2012/10/23 18:05:14.497 xxx.yyy.zzz.aaa:4008 read 34
Current = 0.010 Amps \r\000\n\nCommand>M
2012/10/23 18:05:14.497 P8 LamEMS:ADDR:VOLT_M: Input "Current = 0.010 Amps" mismatch after 0 bytes
2012/10/23 18:05:14.497 P8 LamEMS:ADDR:VOLT_M: got "Current = 0.010 Amps" where "Voltage = " was expected
2012/10/23 18:05:14.497 xxx.yyy.zzz.aaa:4008 write 3
MC\n
2012/10/23 18:05:14.510 xxx.yyy.zzz.aaa:4008 read 5
MC\n\r\000
2012/10/23 18:05:14.510 P8 LamEMS:ADDR:CURR_M: Input "MC" mismatch after 0 bytes
2012/10/23 18:05:14.510 P8 LamEMS:ADDR:CURR_M: got "MC" where "Current = " was expected
2012/10/23 18:05:14.924 xxx.yyy.zzz.aaa:4008 write 3
MC\n
2012/10/23 18:05:15.296 xxx.yyy.zzz.aaa:4008 read 34
Current = 0.010 Amps \r\000\n\nCommand>M
2012/10/23 18:05:15.297 xxx.yyy.zzz.aaa:4008 write 3
MV\n
2012/10/23 18:05:15.309 xxx.yyy.zzz.aaa:4008 read 5
MV\n\r\000
2012/10/23 18:05:15.309 P8 LamEMS:ADDR:VOLT_M: Input "MV" mismatch after 0 bytes
2012/10/23 18:05:15.309 P8 LamEMS:ADDR:VOLT_M: got "MV" where "Voltage = " was expected


If someone has any advice on this issue it would be very helpful for us. 

Thank you. 

Attachment: EMS_01.proto
Description: Binary data

Attachment: EMS_01.vdb
Description: Binary data


Replies:
Re: Lambda EMS mismatch errors Fabian S.
Re: Lambda EMS mismatch errors Rod Nussbaumer

Navigate by Date:
Prev: RE: JCA problems and questions Chu, Paul
Next: installing EPICS James Bryant
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: Trying to get NSLSII's version of CSS Shroff, Kunal