Tony:
It looks like the power supply echoes the commands that are sent to it.
You will need to craft your protocol(s) to read these echoed commands,
or there may be a way to turn off the echoes.
Rod Nussbaumer
ISAC Controls, TRIUMF
Vancouver, Canada
On 10/23/2012 05:17 PM, Anthony Andrews wrote:
###########################################################################
## Start any sequence programs
#seq sncxxx,"user=tonyHost"
epics> 2012/10/23 18:05:13.924 xxx.yyy.zzz.aaa:4008 write 3
MC\n
2012/10/23 18:05:13.936 xxx.yyy.zzz.aaa:4008 read 5
MC\n\r\000
2012/10/23 18:05:13.936 P8 LamEMS:ADDR:CURR_M: Input "MC" mismatch after
0 bytes
2012/10/23 18:05:13.936 P8 LamEMS:ADDR:CURR_M: got "MC" where "Current =
" was expected
2012/10/23 18:05:13.936 xxx.yyy.zzz.aaa:4008 write 3