We’re having problems with the Modbus 2 driver for ASYN I have 2 sets of Modbus networks. One network has a single device, connected from a MOXA 5130 RS-485 converter to a Siemens S7-200 PLC. The other has the same Moxa 5130 MOXA converter with RS-485, connected to a Mirion Radiation monitor and a Apantec Radiation monitor. Originally, I was using Modbus version 1.3 on the system with the S7-200 PLC. It worked for almost a year before upgrading to Modbus 2. After that system had been operating successfully, with no errors, for an extended period, I needed to upgrade the driver so that I could have 2 Modbus devices daisy-chained on a connection. At the same time, in order to limit the number of software revisions in the field, the S7-200 PLC network was upgraded as well. Occasionally, we get error messages similar to the following: ----------------------------------------------------------------------- epics> 2010/10/11 14:30:05.262 drvModbusAsyn::doModbusIO port LPDU3 error calling writeRead, error=radmon5.nsls2.bnl.gov:4001 TCP timeout: Resource temporarily unavailable, nwrite=6/6, nread=0 2010/10/11 14:30:05.262 B-725:VUV<RadMon:2a>Dosage:2 devAsynInt32 process read error 2010/10/11 14:30:05.262 B-725:VUV<RadMon:2b>Dosage:2 devAsynInt32 process read error 2010/10/11 14:30:06.262 drvModbusAsyn::doModbusIO port LPDU3 has I/O error 2010/10/11 14:34:42.310 drvModbusAsyn::doModbusIO port RM1W error calling writeRead, error=radmon5.nsls2.bnl.gov:4001 TCP timeout: Resource temporarily unavailable, nwrite=6/6, nread=0 2010/10/11 14:34:42.310 B-725:VUV<RadMon:1>Dosage:2 devAsynInt32 process read error 2010/10/11 14:34:42.387 modbusInterpose::readIt, CRC error 2010/10/11 14:34:42.387 drvModbusAsyn::doModbusIO port LPDU3 error calling writeRead, error=radmon5.nsls2.bnl.gov:4001 TCP timeout: Resource temporarily unavailable, nwrite=6/6, nread=0 2010/10/11 14:34:42.387 B-725:VUV<RadMon:2a>Dosage:2 devAsynInt32 process read error 2010/10/11 14:34:42.387 B-725:VUV<RadMon:2b>Dosage:2 devAsynInt32 process read error 2010/10/11 14:34:43.310 drvModbusAsyn::doModbusIO port RM1W has I/O error 2010/10/11 14:34:43.387 drvModbusAsyn::doModbusIO port LPDU3 has I/O error ----------------------------------------------------------------------- This only happens occasionally, and happens on both modbus networks, at asynchronous times. All devices in the modbus chain are scanned once per second, and during the time that the errors are –not- occuring, the data stream retrieved is valid. I’ve verified that data is being transmitted, but it looks like occasionally data is not being received and processed correctly. Oh, and also, it only happens if the IOC is using Modbus 2. Modbus 1.3 works without errors, but can only address a single device on each modbus network. Any ideas of where to start looking? David -- "... The Crossbow Project. There's No Defense Like a Good Offense. " - Real Genius (1985) Don't think it exists? Google the Air Force X-37B project.
| ||||||||||||||
ANJ, 12 Oct 2010 |
·
Home
·
News
·
About
·
Base
·
Modules
·
Extensions
·
Distributions
·
Download
·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing · |