Florian Feldbauer <[email protected]> writes:
>
> Do you have an idea how to implement this addressing scheme using only
> _one_ asynPortDriver? The hole device support should to be easy to
> configure...
>
Is this because you need to have only one TCP/IP connection (SOAP?) to
some RPC-server (ISEG iCS?). You could have one port per ISEG module if
you share some connection object with asynPortDriver instances, and use
the address to indicate the channel for the operation.
I think the addressing would be quite clear in this case, since each
port could be configured to know the (crate, node, module) part.
Jani Hakala