1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: motor record: continuously update limit switches
From: "Williams Jr., Ernest L." <[email protected]>
To: "Konrad, Martin" <[email protected]>, "[email protected]" <[email protected]>, "[email protected]" <[email protected]>, "[email protected]" <[email protected]>
Cc: "[email protected]" <[email protected]>
Date: Thu, 8 Aug 2013 16:19:54 -0700
Hi,

Have these changes been applied to SVN repository for the motor module?
I was hoping that we could pull your bug fixes from SVN HEAD

Cheers,
Ernest

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Konrad, Martin
Sent: Thursday, August 08, 2013 7:55 AM
To: [email protected]; [email protected]; [email protected]
Cc: [email protected]
Subject: Re: motor record: continuously update limit switches

Dear MotorRecord maintainers,
you can find my fix for the issue here:

https://github.com/mark0n/motorRecord

The repository also includes patches to eliminate some compiler warnings. Feel free to cherry pick.

Please let me know if you have any concerns regarding the changes I made.

Thanks,

Martin

On 07/29/2013 03:18 PM, Konrad, Martin wrote:
> Hi,
>> I tested the OMS-58 and MSTA does update if the limit is disconnected 
>> and STUP is set to 1.
> Mark, thanks for providing these details. With your information I was 
> able to track the issue further down:
> Even with the "sendMsg = false;" line commented out in the device 
> support, the MSTA field does not show a change in the limit-switch 
> status while the motor is stopped (as far as I can see commenting out 
> this line has no effect on the behavior at all).
>
> Sniffing the TCP connection between the IOC and the motor controller I 
> learned that the issue is caused by the behavior of the motor 
> controller which only transmits some sort of a "limit switch hit while moving"
> status as a response to the TAS (transmit axis data) command. In other
> words: The limit status in this message is not updated while the motor 
> is stopped and triggering STUP is pretty useless (at least regarding 
> the limit switches)...
>
> Nevertheless it is possible to read out the state of the limit inputs 
> with the TLIM (transmit limits) or LIMFNC (input function for limit
> inputs) commands. Here is an example:
> # all limit switches in "ok" position:
>> TAS
> *TAS0000_0100_0000_0001_0000_0000_0000_0000
>>
>> TLIM
> *TLIM110
>>
>> LIMFNC
> *LIMFNC1-R POS LIMIT INPUT       - STATUS ON
> *LIMFNC2-S NEG LIMIT INPUT       - STATUS ON
> *LIMFNC3-T HOME LIMIT INPUT      - STATUS OFF
>
> # negative limit switch pressed (while motor stopped):
>> TAS
> *TAS0000_0100_0000_0001_0000_0000_0000_0000
>>
>> TLIM
> *TLIM100
>>
>> LIMFNC
> *LIMFNC1-R POS LIMIT INPUT       - STATUS ON
> *LIMFNC2-S NEG LIMIT INPUT       - STATUS OFF
> *LIMFNC3-T HOME LIMIT INPUT      - STATUS OFF
>
> As far as I can see the PC6K device support should use one of TLIM or 
> LIMFNC to determine the status of the limit switches. Can anyone of 
> the maintainers confirm that? - I don't want to make changes to the 
> code that do not have a chance to be included into the next version of 
> motor record...
>
> Thanks for your help,
>
> Martin
>
>
>




Replies:
Re: motor record: continuously update limit switches Ron Sluiter
References:
motor record: continuously update limit switches Konrad, Martin
Re: motor record: continuously update limit switches Konrad, Martin
Re: motor record: continuously update limit switches Konrad, Martin

Navigate by Date:
Prev: Re: motorRecord simulation & STUP field Kevin Peterson
Next: [asyn] link already open! Pavel Maslov
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: motor record: continuously update limit switches Konrad, Martin
Next: Re: motor record: continuously update limit switches Ron Sluiter
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 20 Apr 2015 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·