1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Implementation of alarm handlers by EPICS users
From: Kate Feng <[email protected]>
To: "Munro Jr, John K." <[email protected]>
Cc: tech-talk <[email protected]>
Date: Mon, 12 Jan 2004 10:06:14 -0500
On Dec 12, 2003, John Munro wrote :
> Maybe one solution should not be expected to fit all situations.
> .........
> A particular area of interest is the use of audible alarms.  What is
> being used?  How are they implemented?


For the DUV-FEL at NSLS, instead of relying on the network, the
safety personnel prefers the usage of cables carrying TTL signals
between the alarm and the bit I/Os of the radiation monitor IOC.
Thus the hardware engineer implemented an alarm box, which features
1) a heartbeat LED toggled periodically via a PV to indicate that the
IOC is up, 2) one audible alarm and one LED to be activated in case of
heartbeat failure (e.g. IOC is down), 3) one audible alarm and one LED
to be activated via PVs if the IOC detected that the radiation level
of any target location exceeded the limit, 4) buttons to reset the
sounds and lights of alarms.  The buttons can be implemented either
via hardware integrated into the box or via PVs and GUIs, although
the former option eliminates the usage of a computer to reset alarms.
This alarm box is meant for the personnel who operate in the
control room.


Maren Purves wrote :
> we here aren't so much interested in audible alarms as we need to
notify
> people remotely, so we're doing it by email, like this:
> alh -s /ukirtdata/epics_data/alhConfig/ufti.alhConfig &


Good idea!  This way the safety personnel who work in the office can be
informed automatically as well.


Kate



Navigate by Date:
Prev: Choice of Power PC VME cards Singleton, SJ (Steve)
Next: RE: PV reconnect logic question Jeff Hill
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Choice of Power PC VME cards Korhonen Timo
Next: Epics server stop Liyu, Andrei
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024