1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: linear conversion in ai & ao records
From: [email protected] (Tim Mooney)
To: [email protected]
Date: Tue, 14 Jul 1998 14:59:36 -0500
FYI,

The most recent Record Reference Manual claims analog output scaling happens
as follows:

RVAL = RVAL * ASLO + AOFF

The 3.13.x code actually does something different:

RVAL = (RVAL - AOFF) / ASLO

Tim Mooney