Mark – Should destructors be being called when Area Detectors shutdown (I don’t seem to see that happening) or do you have to do what a few AD’s have done and create an exit handler if you need to perform any sort of cleanup. I have a camera with a FPGA which runs *hot* when it is being used, so shutting it down when the AD exits or aborts might prevent it from baking itself. Trace code never seems to be hit in the destructor. |