1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Switched PDUs with EPICS support
From: "[email protected]" <[email protected]>
To: Žiga Oven <[email protected]>
Cc: [email protected]
Date: Wed, 10 May 2017 09:06:11 +0200 (CEST)

Hi,
few months ago I developed an EPICS IOC for ATEN PDU
(PE8208 - metered and switched) using SNMP device support
module (https://groups.nscl.msu.edu/controls/files/devSnmp.html);

source code available here:

	https://github.com/gtortone/ATEN-EPICS

Regards,
Gennaro


On Tue, 9 May 2017, Žiga Oven wrote:

Hi All,

We are looking for alternative to APC switched PDUs as we would like to have cord longer than standard APC length of 12 feet.
http://www.apc.com/shop/us/en/products/Rack-PDU-Switched-1U-15A-100-120V-8-5-15/P-AP7900B

I have checked the EPICS modules page and I have found several other options with existing support, but they all look a bit outdated (based on part numbers on the page and cross-referencing them with current vendor part numbers).

Are there other switched PDUs with EPICS support in use besides APC?

Thanks,

Žiga



--
Gennaro Tortone
INFN Napoli
Italy
tel: +39 81 676169

"Computer Science is no more about computers
    than astronomy is about telescopes."
    - Edsger Dijkstra

Replies:
Re: Switched PDUs with EPICS support Bruce Hill
References:
Switched PDUs with EPICS support Žiga Oven

Navigate by Date:
Prev: Re: Switched PDUs with EPICS support Tom Slejko
Next: RE: AreaDetector bindings and RBV propagation Iain Marcuson
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Switched PDUs with EPICS support Tomaž Šuštar
Next: Re: Switched PDUs with EPICS support Bruce Hill
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
ANJ, 21 Dec 2017 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·