EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Multiple NDPluginPva issues
From: Alexander Söderqvist <[email protected]>
To: [email protected]
Date: Tue, 8 Nov 2016 16:38:44 +0100
Hi all,

I am at ESS running an IOC with 2 pva plugins both connected to the simDetector:

# Create a simDetector driver
# simDetectorConfig(const char *portName, int maxSizeX, int maxSizeY, int dataType,
#                   int maxBuffers, int maxMemory, int priority, int stackSize)
simDetectorConfig("DMSCSIMDET", 500, 500, 1, 0, 0)
dbLoadRecords("simDetector.template", "P=DMSC:, R=CAM-, PORT=DMSCSIMDET, ADDR=0, TIMEOUT=1")
#create pva plugin
NDPvaConfigure(DMSCPVA, 20, 0, "DMSCSIMDET", 0, "DMSC:IMAGE", 0)
VERSION : pvAccess Server v4.1.2
PROVIDER_NAMES : local
BEACON_ADDR_LIST :
AUTO_BEACON_ADDR_LIST : 1
BEACON_PERIOD : 15
BROADCAST_PORT : 5076
SERVER_PORT : 5075
RCV_BUFFER_SIZE : 16384
IGNORE_ADDR_LIST:
STATE : INITIALIZED
dbLoadRecords("NDPva.template", "P=DMSC:, R=PVA-, PORT=DMSCPVA, ADDR=0, TIMEOUT=1, NDARRAY_PORT=DMSCSIMDET")
#create pva plugin
NDPvaConfigure(DMSCPVA2, 20, 0, "DMSCSIMDET", 0, "DMSC:IMAGE2", 0)
2016-11-08T16:33:54.789 Using dynamically assigned TCP port 52363.
VERSION : pvAccess Server v4.1.2
PROVIDER_NAMES : local
BEACON_ADDR_LIST :
AUTO_BEACON_ADDR_LIST : 1
BEACON_PERIOD : 15
BROADCAST_PORT : 5076
SERVER_PORT : 52363
RCV_BUFFER_SIZE : 16384
IGNORE_ADDR_LIST:
STATE : INITIALIZED
dbLoadRecords("NDPva.template", "P=DMSC:, R=PVA2-, PORT=DMSCPVA2, ADDR=0, TIMEOUT=1, NDARRAY_PORT=DMSCSIMDET")


As you can see it start 2 pvAccess servers.

Monitoring one array sees multiple instance of the pv:
pvget -m DMSC:IMAGE2
[ChannelRequesterImpl] message(More than one channel with name 'DMSC:IMAGE2' detected, connected to: 194.47.240.7:52834, ignored: 194.47.240.7:5075, warning)
DMSC:IMAGE2
structure
    union value
        (none)

Listing the servers shows the 2 pvAccess servers (Which yo):
pvlist
GUID 0x7EE8215800000000799BA728, version 1: tcp@[x.x.x.x:5075]
GUID 0x7EE82158000000008AD62829, version 1: tcp@[x.x.x.x:52834]

Listing pvs on each server shows that both are publishing the same PVs.
pvlist 0x7EE8215800000000799BA728
DMSC:IMAGE
DMSC:IMAGE2

pvlist 0x7EE82158000000008AD62829
DMSC:IMAGE
DMSC:IMAGE2

Has anyone tried running 2 NDPluginPvas in the same IOC before? Are you supposed to start multiple pvAccess servers in the same IOC?

Note that we are using our own build system, and it might be an issue there.

Regards,
Alexander Söderqvist

Replies:
Re: Multiple NDPluginPva issues Pearson, Matthew R.

Navigate by Date:
Prev: Re: processCallbacks() never called in areaDetector plugin Alexander Söderqvist
Next: Packed Data Message Formats With Fixed-Length Strings Iain Marcuson
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: processCallbacks() never called in areaDetector plugin Ben Franksen
Next: Re: Multiple NDPluginPva issues Pearson, Matthew R.
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 08 Nov 2016 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·