Experimental Physics and
| |||||||||||||||
|
Hello... Happy New year.1 question i saw field(SCAN, "I/O Intr") in record .. .2016/01/04 10:05:09.128 192.100.100.20:4016 write 8 !53ALL\r\n 2016/01/04 10:05:09.163 192.100.100.20:4016 read 15 ?531000010100\r\n 2016/01/04 10:05:10.276 MX2_13 BL5C:SCREENS:Measure: No reply from device within 2000 ms 2016/01/04 10:05:10.372 MX1_9 BL5C:NOZZLE:GetCryoSolAllSta: No reply from device within 1200 ms 2016/01/04 10:05:10.379 192.100.100.20:4016 write 8 !53ALL\r\n 2016/01/04 10:05:10.414 192.100.100.20:4016 read 15 ?531000010100\r\n 2016/01/04 10:05:11.624 MX1_9 BL5C:NOZZLE:GetCryoSolAllSta: No reply from device within 1200 ms 2016/01/04 10:05:11.631 192.100.100.20:4016 write 8 !53ALL\r\n 2016/01/04 10:05:11.666 192.100.100.20:4016 read 15 ?531000010100\r\n 2016/01/04 10:05:12.875 MX1_9 BL5C:NOZZLE:GetCryoSolAllSta: No reply from device within 1200 ms db file... # Reading # ### Get All Status of Nozzle Exchanger start ### record(bi, "$(P)$(D):GetRemoteAllSta") { field(DESC, "Local/Remote All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetRemoteAllSta $(PORT) $(A)") field(ZNAM, "Local") field(ONAM, "Remote") field(SCAN, ".2 second") field(FLNK, "$(P)$(D):GetCryoSolAllSta") } record(mbbi, "$(P)$(D):GetCryoSolAllSta") { field(DESC, "Cryo Solenoid All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetCryoSolAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "Mid") field( THVL, "3") field( THST, "Failure") field(FLNK, "$(P)$(D):GetCryoOnSensorAllSta") #field(SCAN, "I/O Intr") } record(mbbi, "$(P)$(D):GetHC1SolAllSta") { field(DESC, "HC1 Solenoid All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetHC1SolAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "Mid") field( THVL, "3") field( THST, "Failure") field(SCAN, "I/O Intr") } record(bi, "$(P)$(D):GetShutterSolAllSta") { field(DESC, "Shutter Solenoid All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetShutterSolAllSta $(PORT) $(A)") field(ZNAM, "Off") field(ONAM, "On") field(SCAN, "I/O Intr") } record(mbbi, "$(P)$(D):GetCryoOnSensorAllSta") { field(DESC, "Cryo Cylinder On Sensor All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetCryoOnSensorAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "On Going") #field(SCAN, "I/O Intr") } record(mbbi, "$(P)$(D):GetCryoOffSensorAllSta") { field(DESC, "Cryo Cylinder Off Sensor All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetCryoOffSensorAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "Off Going") field(SCAN, "I/O Intr") } record(mbbi, "$(P)$(D):GetHC1OnSensorAllSta") { field(DESC, "HC1 Cylinder On Sensor All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetHC1OnSensorAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "On Going") field(SCAN, "I/O Intr") } record(mbbi, "$(P)$(D):GetHC1OffSensorAllSta") { field(DESC, "HC1 Cylinder Off Sensor All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetHC1OffSensorAllSta $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Off") field( ONVL, "1") field( ONST, "On") field( TWVL, "2") field( TWST, "Off Going") field(SCAN, "I/O Intr") } record(bi, "$(P)$(D):GetCryoBackAllSta") { field(DESC, "Cryo Back All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetCryoBackAllSta $(PORT) $(A)") field(ZNAM, "Back Off") field(ONAM, "Back On") field(SCAN, "I/O Intr") } record(bi, "$(P)$(D):GetHC1BackAllSta") { field(DESC, "HC1 Back All Status") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto GetHC1BackAllSta $(PORT) $(A)") field(ZNAM, "Back Off") field(ONAM, "Back On") field(SCAN, "I/O Intr") } ### Get All Status of Nozzle Exchanger end ### record(bo,"$(P)$(D):SetCryoNozzleOn") { field(DESC, "Cryo Nozzle ON") field(FLNK, "$(P)$(D):GetCryoNozzleOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetCryoNozzleOn $(PORT) $(A)") } record(bi,"$(P)$(D):GetCryoNozzleOn") { field(DESC, "Cryo Nozzle ON") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetCryoNozzleOn $(PORT) $(A)") } record(bo,"$(P)$(D):SetCryoNozzleOff") { field(DESC, "Cryo Nozzle OFF") field(FLNK, "$(P)$(D):GetCryoNozzleOff PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetCryoNozzleOff $(PORT) $(A)") } record(bi,"$(P)$(D):GetCryoNozzleOff") { field(DESC, "Cryo Nozzle Off") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetCryoNozzleOff $(PORT) $(A)") } record(bo,"$(P)$(D):SetHC1NozzleOn") { field(DESC, "HC1 Nozzle On") field(FLNK, "$(P)$(D):GetHC1NozzleOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetHC1NozzleOn $(PORT) $(A)") } record(bi,"$(P)$(D):GetHC1NozzleOn") { field(DESC, "HC1 Nozzle On") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetHC1NozzleOn $(PORT) $(A)") } record(bo,"$(P)$(D):SetHC1NozzleOff") { field(DESC, "HC1 Nozzle Off") field(FLNK, "$(P)$(D):GetHC1NozzleOff PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetHC1NozzleOff $(PORT) $(A)") } record(bi,"$(P)$(D):GetHC1NozzleOff") { field(DESC, "HC1 Nozzle Off") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetHC1NozzleOff $(PORT) $(A)") } record(bo,"$(P)$(D):SetNozzleBackOn") { field(DESC, "Nozzle Back On") field(FLNK, "$(P)$(D):GetNozzleBackOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetNozzleBackOn $(PORT) $(A)") } record(mbbi,"$(P)$(D):GetNozzleBackOn") { field(DESC, "Nozzle Back On") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetNozzleBackOn $(PORT) $(A)") field( ZRVL, "0") field( ZRST, "Error") field( ONVL, "1") field( ONST, "Cryo Back Ok") field( TWVL, "2") field( TWST, "HC1 Back Ok") } record(bo,"$(P)$(D):SetNozzleBackOff") { field(DESC, "Nozzle Back Off") field(FLNK, "$(P)$(D):GetNozzleBackOff PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetNozzleBackOff $(PORT) $(A)") } record(bi,"$(P)$(D):GetNozzleBackOff") { field(DESC, "Nozzle Back Off") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetNozzleBackOff $(PORT) $(A)") } record(bo,"$(P)$(D):SetCryoNozzleAutoOn") { field(DESC, "Cryo Nozzle Auto On") field(FLNK, "$(P)$(D):GetCryoNozzleAutoOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetCryoNozzleAutoOn $(PORT) $(A)") } record(bi,"$(P)$(D):GetCryoNozzleAutoOn") { field(DESC, "Cryo Nozzle Auto On") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetCryoNozzleAutoOn $(PORT) $(A)") } record(bo,"$(P)$(D):SetHC1NozzleAutoOn") { field(DESC, "HC1 Nozzle Auto On") field(FLNK, "$(P)$(D):GetHC1NozzleAutoOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetHC1NozzleAutoOn $(PORT) $(A)") } record(bi,"$(P)$(D):GetHC1NozzleAutoOn") { field(DESC, "HC1 Nozzle Auto On") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetHC1NozzleAutoOn $(PORT) $(A)") } record(bo,"$(P)$(D):SetCryoShutterOn") { field(DESC, "Cryo Shutter On") field(FLNK, "$(P)$(D):GetCryoShutterOn PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetCryoShutterOn $(PORT) $(A)") } record(bi,"$(P)$(D):GetCryoShutterOn") { field(DESC, "Cryo Shutter On") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetCryoShutterOn $(PORT) $(A)") } record(bo,"$(P)$(D):SetCryoShutterOff") { field(DESC, "Cryo Shutter Off") field(FLNK, "$(P)$(D):GetCryoShutterOff PP") # field(DTYP, "stream") # field(OUT, "@devNozzleExchange.proto SetCryoShutterOff $(PORT) $(A)") } record(bi,"$(P)$(D):GetCryoShutterOff") { field(DESC, "Cryo Shutter Off") field(DTYP, "stream") field(INP, "@devNozzleExchange.proto SetCryoShutterOff $(PORT) $(A)") } record(bo,"$(P)$(D):SetSystemReset") { field(DESC, "System Reset") # field(FLNK, "$(P)$(D):GetSystemReset PP") field(DTYP, "stream") field(OUT, "@devNozzleExchange.proto SetSystemReset $(PORT) $(A)") } #record(bi,"$(P)$(D):GetSystemReset") #{ # field(DESC, "System Reset") # field(DTYP, "stream") # field(INP, "@devNozzleExchange.proto SetSystemReset $(PORT) $(A)") #} record(ao, "$(P)$(D):Mode") { field(DESC, "Control Mode") field(PREC, "0") } proto file @writetimeout { disconnect; }
@replytimeout { disconnect; } @readtimeout { disconnect; } @mismatch { disconnect; } ReplyTimeout = 1200; InTerminator = CR LF; OutTerminator = CR LF; # # Measure current # GetRemoteSta { out "!50SWS"; in "?50%1d"; ExtraInput = Ignore; } GetCryoSolSta { out "!51SOL"; in "?51%1d%*2d"; ExtraInput = Ignore; } GetHC1SolSta { in "?51%*1d%1d%*1d"; ExtraInput = Ignore; } GetShutterSolSta { in "?51%*2d%1d"; ExtraInput = Ignore; } GetCryoOnSensorSta { out "!52POS"; in "?52%1d%*5d"; ExtraInput = Ignore; } GetCryoOffSensorSta { in "?52%*1d%1d%*4d"; ExtraInput = Ignore; } GetHC1OnSensorSta { in "?52%*2d%1d%*3d"; ExtraInput = Ignore; } GetHC1OffSensorSta { in "?52%*3d%1d%*2d"; ExtraInput = Ignore; } GetCryoBackSta { in "?52%*4d%1d%*1d"; ExtraInput = Ignore; } GetHC1BackSta { in "?52%*5d%1d"; ExtraInput = Ignore; } ### Get All Status of Nozzle Exchanger start ### GetRemoteAllSta{ out "!53ALL"; in "?53%1d%*9d"; ExtranInput = Ignore; } GetCryoSolAllSta{ in "?53%*1d%1d%*8d"; ExtranInput = Ignore; } GetHC1SolAllSta{ in "?53%*2d%1d%*7d"; ExtranInput = Ignore; } GetShutterSolAllSta{ in "?53%*3d%1d%*6d"; ExtranInput = Ignore; } GetCryoOnSensorAllSta { in "?53%*4d%1d%*5d"; ExtraInput = Ignore; } GetCryoOffSensorAllSta { in "?53%*5d%1d%*4d"; ExtraInput = Ignore; } GetHC1OnSensorAllSta { in "?53%*6d%1d%*3d"; ExtraInput = Ignore; } GetHC1OffSensorAllSta { in "?53%*7d%1d%*2d"; ExtraInput = Ignore; } GetCryoBackAllSta { in "?53%*8d%1d%*1d"; ExtraInput = Ignore; } GetHC1BackAllSta { in "?53%*9d%1d"; ExtraInput = Ignore; } ### Get All Status of Nozzle Exchanger end ### GetRobotBackOnSta{ out "!55RBS"; in "?55%1d%*1d"; ExtraInput = Ignore; } GetRobotNozzleOffSta{ in "?55%*1d%1d"; ExtraInput = Ignore; } SetCryoNozzleOn { out "!10CON"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetCryoNozzleOff { out "!11COF"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetHC1NozzleON { out "!13HON"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetHC1NozzleOff { out "!14HOF"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetNozzleBackOn { out "!15BON"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetNozzleBackOff { out "!16BOF"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetCryoNozzleAutoOn { out "!17ACN"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetHC1NozzleAutoOn { out "!18AHN"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetCryoShutterOn { out "!19CSO"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetCryoShutterOff { out "!20CSF"; in "%1d=%*2c"; @mismatch { in "Error=%1d";} } SetSystemReset { out "!21RST"; # in "%1d=%*2c"; # @mismatch { in "Error=%1d";} } I want to know why not ? Please help me..
| ||||||||||||||
ANJ, 15 Jul 2016 |
·
Home
·
News
·
About
·
Base
·
Modules
·
Extensions
·
Distributions
·
Download
·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing · |