Hiroshi, Your recent transferArray record was just what I needed for a recent application, thank you for making it available. In the .dbd file: field(OUT,DBF_INLINK) should be field(OUT,DBF_OUTLINK) This is used by visual DB editors. -ps Subject: The transferArray record From: <[email protected]> To: <[email protected]> Date: Wed, 01 Oct 2014 19:31:50 +0900 Dear EPICS colleagues, Here I would like to introduce the new record which is developed at KEK. The "transferArray" record copies a part of waveform elements and pastes them into the other waveform. It is developed for a specific use for KEK accelerator, especially, LINAC. However, I believe it can be used for the various purposes. We prepared source and manual on our web so that you can easily utilize. I hope it helps you. Please have a look and use in your work. Also please ask us anything about this record. Best regards, Hiroshi Kaji, KEK Accelerator Control Group.
| ||||||||||||||