I just updated the github repository, with the equivalent of the tar ball.
Peter
Dr. Peter Zumbruch
EE - department / Controls group
E-Mail: [email protected]
Tel: +49-(6159)-71-1435 / Fax: +49-(6159)-71-2986
GSI Helmholtzzentrum für Schwerionenforschung GmbH
Planckstraße 1 / 64291 Darmstadt / www.gsi.de
Gesellschaft mit beschränkter Haftung
Sitz der Gesellschaft: Darmstadt
Handelsregister: Amtsgericht Darmstadt, HRB 1528
Geschäftsführung: Professor Dr. Dr. h.c. mult. Horst Stöcker, Ursula Weyrich
Vorsitzenderdes Aufsichtsrates: St Dr. Georg Schütte
Stellvertreter: Ministerialdirigent Dr. Rolf Bernhardt
> -----Ursprüngliche Nachricht-----
> Von: Florian Feldbauer [mailto:[email protected]]
> Gesendet: Donnerstag, 26. Februar 2015 14:26
> An: Zumbruch, Peter Dr.; EPICS Tech Talk
> Betreff: Re: AW: EPICS device support for DIM
>
> Thanks!
> I have found your code on the GSI-Wiki pages.
> https://wiki.gsi.de/foswiki/pub/Epics/EpicsDimInterface/EPICS-DIM-
> Interface.tar.bz2
>
> Your repository on github doesn't contain any code.
>
> Cheers,
> Florian
>
>
> On 02/26/2015 02:20 PM, Zumbruch, Peter Dr. wrote:
> > Dear Florian,
> > some years ago I did this implementation.
> >
> > https://github.com/zumbruch/EPICS-DIM
> >
> > Best regards,
> > Peter
> >
> > Dr. Peter Zumbruch
> > EE - department / Controls group
> > E-Mail: [email protected]
> > Tel: +49-(6159)-71-1435 / Fax: +49-(6159)-71-2986 GSI Helmholtzzentrum
> > für Schwerionenforschung GmbH Planckstraße 1 / 64291 Darmstadt /
> > www.gsi.de Gesellschaft mit beschränkter Haftung
> >
> > Sitz der Gesellschaft: Darmstadt
> > Handelsregister: Amtsgericht Darmstadt, HRB 1528
> > Geschäftsführung: Professor Dr. Dr. h.c. mult. Horst Stöcker, Ursula
> > Weyrich
> >
> > Vorsitzenderdes Aufsichtsrates: St Dr. Georg Schütte
> > Stellvertreter: Ministerialdirigent Dr. Rolf Bernhardt
> >
> >
> >> -----Ursprüngliche Nachricht-----
> >> Von: [email protected] [mailto:tech-talk-
> >> [email protected]] Im Auftrag von Florian Feldbauer
> >> Gesendet: Donnerstag, 26. Februar 2015 14:15
> >> An: EPICS Tech Talk
> >> Betreff: EPICS device support for DIM
> >>
> >> Hey all,
> >>
> >> you would like to use the DIM protocol
> >> http://dim.web.cern.ch/dim/index.html
> >> to communicate with our FPGAs of the front-end electronics of our
> detector.
> >> These front-end boards also contain data belonging to the Detector
> >> Control System handled by EPICS.
> >> So we would need a device support for DIM. Does anyone has written
> >> something in this direction already?
> >>
> >> If not, is there some easy to follow documentation about writing I/O
> >> interrupt handler for the device support?
> >>
> >> I have programmed a few small device support routines already. But
> >> never with I/O interrupt handling...
> >>
> >> Best regards,
> >> Florian
> >>
> >> --
> >> ----------------------------------------
> >> | Dr. Florian Feldbauer |
> >> | |
> >> | Helmholtz-Institut Mainz / |
> >> | Johannes Gutenberg-Universität Mainz |
> >> | Johann-Joachim-Becher-Weg 36 |
> >> | D-55128 Mainz |
> >> | |
> >> | Office: SB1 / 00-321 |
> >> | Phone: (+49)6131 / 39-29605 |
> >> ----------------------------------------
>
>
> --
> ----------------------------------------
> | Dr. Florian Feldbauer |
> | |
> | Helmholtz-Institut Mainz / |
> | Johannes Gutenberg-Universität Mainz |
> | Johann-Joachim-Becher-Weg 36 |
> | D-55128 Mainz |
> | |
> | Office: SB1 / 00-321 |
> | Phone: (+49)6131 / 39-29605 |
> ----------------------------------------
- References:
- EPICS device support for DIM Florian Feldbauer
- AW: EPICS device support for DIM Zumbruch, Peter Dr.
- Re: AW: EPICS device support for DIM Florian Feldbauer
- Navigate by Date:
- Prev:
Re: Error in compiling areaDetector Heinz Junkes
- Next:
RE: RE: Error in compiling areaDetector Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: AW: EPICS device support for DIM Florian Feldbauer
- Next:
Streamdevice IOC for Agilent XGS600 Vacuum Gauge Controller Alex Wallace
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
|