1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: TPG261 : "message too small=0" for EPICS
From: Sanguk Won <[email protected]>
To: [email protected]
Cc: Song Jihye <[email protected]>
Date: Tue, 27 Aug 2013 21:09:38 +0900
Dear all,

I am just starting to learn the EPICS.

In order to monitoring vacuum level of my chamber, I used pfeiffer TPG216 single gauge.

I installed "baseR-3.14.12.1" and  "synApps_5.6".
Directory is following 

$HOME(or any directory where you want)/EPICS/base
$HOME(or any directory where you want)/EPICS/modules/synApps_5_6/support/ip-2-13
$HOME(or any directory where you want)/EPICS/modules/synApps_5_6/support/asyn-4-18
$HOME(or any directory where you want)/EPICS/modules/synApps_5_6/support/ipac-2-11
$HOME(or any directory where you want)/EPICS/modules/synApps_5_6/support/seq-2-1-3 

and so on.


I would like to use "ip" which have db and sorce codes for TPG261 model.
 when I execute ipApp with st.cmd, what only I can get is following messages.


2013/08/22 21:17:33.179 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:SP2S message too small=0
2013/08/22 21:17:35.279 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:SP1S message too small=0
2013/08/22 21:17:37.379 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:SP2V message too small=0
2013/08/22 21:17:39.479 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:STATUS message too small=0
2013/08/22 21:17:41.579 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:PRES message too small=0
2013/08/22 21:17:43.679 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:UNIT message too small=0
2013/08/22 21:17:45.779 devTPG261::devTPG261Callback Cmd Vacuum:tpg261:SP2S message too small=0


Could you help me with this problem ?


linux(Ubuntu12.04 LTS) computer and TPG261 connection is not, Should any device be connected?


Thanks
-- 
Sanguk Won



Replies:
RE: TPG261 : "message too small=0" for EPICS Mark Rivers

Navigate by Date:
Prev: Re: StreamDevice communication problems Dirk Zimoch
Next: Re: How to execute opi files? Kasemir, Kay
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: How to execute opi files? Kasemir, Kay
Next: RE: TPG261 : "message too small=0" for EPICS Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 20 Apr 2015 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·