Subject: RE: medm and Xming on Windows 7 64 bit
From: Mark Rivers <rivers@cars.uchicago.edu>
To: "'Troy Lutes'" <lutes@aps.anl.gov>, "tech-talk@aps.anl.gov" <tech-talk@aps.anl.gov>
Date: Thu, 24 May 2012 17:37:39 +0000
Hi Troy,

I am quite sure I ran into that same problem on a Windows 7 32-bit system recently.

I worked around the problem by not installing the 2011 1.42 or 1.41 builds of the EPICS Windows Tools, but rather installing the 1.40 build from 2007.  I did not take much time to investigate, but I'm quite sure that worked.

Mark


-----Original Message-----
From: tech-talk-bounces@aps.anl.gov [mailto:tech-talk-bounces@aps.anl.gov] On Behalf Of Troy Lutes
Sent: Wednesday, May 23, 2012 3:04 PM
To: tech-talk@aps.anl.gov
Subject: medm and Xming on Windows 7 64 bit

We are setting up an IOC for HPSync. The IOC seems to startup fine, but there are problems with the display. We have installed Xming as described in:
http://controls.web.psi.ch/cgi-bin/twiki/view/Main/HowToSetupEPICSWin32
Probe, alarm handler, strip tool, etc all work fine from the icons in the win32 tools folder. 

Medm gives the following error in the Xconsole
[medm]

MEDM Version 3.1.5: Loading aliased fonts.................

SIGSEGV

Does anybody have experience with Xming and medm?
Thanks in advance,
Troy

-- 
Troy Lutes 
Linux Systems Administrator
Advanced Photon Source 
Argonne National Laboratory
(630)252-1345


Replies:
Re: medm and Xming on Windows 7 64 bit Pavel Masloff
References:
medm and Xming on Windows 7 64 bit Troy Lutes

Navigate by Date:
Prev: Re: "@init handler failed" , "Record initialization failed" and "No reply from device within 1000 ms" Eric Norum
Next: Re: medm and Xming on Windows 7 64 bit Pavel Masloff
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017 
Navigate by Thread:
Prev: Re: medm and Xming on Windows 7 64 bit Paul Sichta
Next: Re: medm and Xming on Windows 7 64 bit Pavel Masloff
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·