1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 <2012> 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 <2012> 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: 'reconnect' in asyn / streamDevice |
From: | Eric Norum <[email protected]> |
To: | Emmanuel Mayssat <[email protected]> |
Cc: | epics <[email protected]> |
Date: | Fri, 11 May 2012 09:59:38 -0700 |
You should specify this "connect per transaction" when configuring the ASYN port -- here's the salient portion of the documentation -- note the 'HTTP' protocol option:TCP/IP or UDP/IP PortThe drvAsynIPPort driver supports devices which communicate over a TCP/IP or UDP/IP connection. A typical example is a device connected through an Ethernet/Serial converter box. TCP/IP or UDP/IP connections are configured with the drvAsynIPPortConfigure command: drvAsynIPPortConfigure("portName","hostInfo",priority,noAutoConnect, noProcessEos) where the arguments are:
On May 11, 2012, at 9:51 AM, Emmanuel Mayssat wrote:
--
Eric Norum [email protected] |