Subject: Cosylab MicroIOC/BLM Calibration procedure confusion
From: Josh Stein <stein@aps.anl.gov>
To: tech-talk@aps.anl.gov
Date: Wed, 25 Apr 2012 12:02:08 -0500
Greetings all,

I have a question needing rapid response - hence my wasting tech-talk bandwidth instead of contacting Cosylab directly (which I will do also). I have a Cosylab BLM system consisting of one of their MicroIOCS and a Bergoz detector. One of the procedures to follow when first using this system is a calibration involving setting two trimmer potentiometers.

In the (Cosylab) manual, they refer to setting the output of a particular detector 'side' to 10KHz - however all of the PVs for that device talk in "Counts". I'm not sure how to do a proper calibration when all the software returns are counts per time-slot.

For now, I just changed my time-slot to 1ms (about the longest duration possible) and adjusted the potentiometers to readback a value of (close to) 10 (figuring that 10 counts in 1ms = 10,000 counts in 1 second). This was pretty difficult - I feel as if I am dangerously close to an 'edge' of the trimmer pot and therefore in a non-linear region. Needless to say, I am not confident I have done this correctly.

Does anyone out there have experience with this system? We have an opportunity today to do some experiments - hence my somewhat frantic email.

TIA,
--Josh


Navigate by Date:
Prev: Presentation slides for EPICS Training Available Williams Jr., Ernest L.
Next: Re: Presentation slides for EPICS Training Available Dudley, David
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014 
Navigate by Thread:
Prev: RE: Presentation slides for EPICS Training Available Williams Jr., Ernest L.
Next: Re: Fwd: Cosylab MicroIOC/BLM Calibration procedure confusion Uwe Bonnes
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· EPICSv4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·