1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: cothread ca_nothing
From: "Shen, Guobao" <[email protected]>
To: "'tech-talk'" <[email protected]>, [email protected]
Date: Tue, 06 Mar 2012 12:41:08 -0500
Hi Michael,
Recently I found that in cothread, if there is an exception in caput(pv[], value[],...), cothread captures the first error message only.
Is there a solution to get all reported errors?

For example, I have a bo record as:

record(bo,"testExample") {
    field(ZNAM,"ON")
    field(ONAM,"OFF")
}

Python code:
import cothread.catools as ca
# testExample2 does not exist
pv = ['testExample','testExample2']
value = ['one','zero']
try:
    res = ca.caput(pv, value, wait=True)
except ca.ca_nothing as e:
    print(e)

The except reports only:
testExample: Channel write request failed

If put the testExample2 first like:
pv = ['testExample2','testExample']

the get:
testExample2: User specified timeout on IO operation expired

Guobao

--
Guobao Shen
Bldg. 902-B, 17 Cornell Avenue
National Synchrotron Light Source II
Brookhaven National Laboratory
Upton, New York 11973
Tel.	: +1 (631) 344 7540
Fax.	: +1 (631) 344 8085
http://www.bnl.gov/nsls2


Navigate by Date:
Prev: Re: EDM Animated Symbol widget Angle PV property question John William Sinclair
Next: Re: "Size of symbol changed" warnings building EPICS Base 3.14.12.2 Dirk Zimoch
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: EDM Animated Symbol widget Angle PV property question John William Sinclair
Next: motor module R6-7-1 released Ron Sluiter
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·