1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: 5500 temp monitor Re: mvme6100 HW issues?
From: Kate Feng <[email protected]>
To: "Kasemir, Kay" <[email protected]>
Cc: "[email protected]" <[email protected]>
Date: Fri, 02 Mar 2012 15:52:35 -0500
On 02/01/2012 12:18 PM, Kasemir, Kay wrote:
Hi:

At SNS, we updated from the MVME2100 to the MVME5500.
The 2100 runs forever without added cooling on extender boards
in open crates in laboratory setups.
The 5500 needs forced cooling right across its heat sinks;
it will otherwise soon overheat.
I am surprised that the mvme5500 overheated.  Did you use
a regular VME crate or a VME64x crate with the mvme5500
board ?  So far, we do not have the overheating problem
on our mvme5500 boards.

Regards,
Kate
Richard Dickson found a way to read a Maxim DS1621 temperature sensor
that's on the 5500 CPU board, which Xihui Chen turned into
an EPICS device driver that we now use on many 5500 CPUs to
monitor their temperature, alarming on some limit.

We could share that if you want to check possible adaption
to the 6100, or see if it's generic enough for use at your
site with 5500 boards.
Thanks,
Kay




Replies:
Re: 5500 temp monitor Re: mvme6100 HW issues? Kasemir, Kay
References:
5500 temp monitor Re: mvme6100 HW issues? Kasemir, Kay

Navigate by Date:
Prev: Re: "Size of symbol changed" warnings building EPICS Base 3.14.12.2 Andrew Johnson
Next: Re: 5500 temp monitor Re: mvme6100 HW issues? Kasemir, Kay
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: 5500 temp monitor Re: mvme6100 HW issues? Kasemir, Kay
Next: Re: 5500 temp monitor Re: mvme6100 HW issues? Kasemir, Kay
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·