1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues
From: "Mark Rivers" <[email protected]>
To: "Adam Gluck" <[email protected]>, <[email protected]>
Date: Fri, 19 Aug 2011 09:49:22 -0500
Is there a firewall running on that machine?

Is there a jcaLibrary.properties file that could be settings things for Java differently than the environment variables for the C utilities?

Mark



-----Original Message-----
From: [email protected] on behalf of Adam Gluck
Sent: Fri 8/19/2011 9:48 AM
To: [email protected]
Subject: Re: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues
 
Hello Kay,

Thanks for the advice but setting the IP address did not help, I am just 
trying to access the variables on my own machine and have tried localhost 
and 127.0.0.1. I did try the logging method and saw at first I was not 
linking correctly to a shared library, but was able to fix the and no 
longer have the error. I don't see any error message about the PV other 
then it saying it is disconnected. I am attaching my log file to see if 
that might help. Thanks once again for the help.

Cheers,

Adam Gluck | Applications Engineer | National Instruments





From:   "Kasemir, Kay" <[email protected]>
To:     Adam Gluck <[email protected]>, "[email protected]" 
<[email protected]>
Date:   08/18/2011 12:16 PM
Subject:        Re: EPICS BOY saying EPICS PV is disconnected even though 
to can be read through the terminal with no issues



Hi again:

Check the menu CSS/Preferences/CSS Core/EPICS for the auto addr. list and
addr list settings.

How do the settings compare to the EPICS_CA_*_ADDR_LIST environment
variables used by the command-line caget?

What if you de-select auto_addr_list and set the address list to the IP of
one of your IOCs? Do you then see the PVs on there?

What if you de-select auto_addr_list and set the address list to the IP of 
a
broadcast address that includes one of your IOCs?

Thanks,
Kay

On 8/18/11 13:14 , "Kay Kasemir" <[email protected]> wrote:
> Hi:
> 
> On 8/18/11 12:28 , "Adam Gluck" <[email protected]> wrote:
> 
>> Hello All,
>> 
>> I have set up EPICS on a Scientific Linux 5.5 computer with the
>> 2.6.18-238.9.1.el5 kernel. I am using CSS to try and read the PV back 
in
>> BOY. When I type the PV in the field then run the OPI it will display a
>> disconnected message and no values are read. If I do the call from the
>> terminal I can read the value back with no issue. I have also tried 
this
>> on a Windows XP machine with the same results. Do you know what steps I
>> could take for further troubleshooting to find out why this is showing
>> disconnected? Or what other information would be helpful is
>> troubleshooting the problem. Thanks for the help.
>> 
>> Cheers,
>> 
>> Adam Gluck | Applications Engineer | National Instruments
>> 





Replies:
Re: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues Ralph Lange
Re: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues Kasemir, Kay
References:
Re: EPICS BOY saying EPICS PV is disconnected even though to can be read through the terminal with no issues Kasemir, Kay
Re: EPICS BOY saying EPICS PV is disconnected even though to can be read through the terminal with no issues Kasemir, Kay
Re: EPICS BOY saying EPICS PV is disconnected even though to can be read through the terminal with no issues Adam Gluck

Navigate by Date:
Prev: Re: EPICS BOY saying EPICS PV is disconnected even though to can be read through the terminal with no issues Adam Gluck
Next: Re: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues Ralph Lange
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: EPICS BOY saying EPICS PV is disconnected even though to can be read through the terminal with no issues Adam Gluck
Next: Re: EPICS BOY saying EPICS PV is disconnected even though to can beread through the terminal with no issues Ralph Lange
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·