Subject: |
Re: radiation damage to electronics inside accelerator tunnel? |
From: |
Benjamin Franksen <[email protected]> |
To: |
<[email protected]> |
Date: |
Thu, 16 Jun 2011 01:54:19 +0200 |
Am Dienstag, 14. Juni 2011, um 21:42:09 schrieb Hu, Yong:
> Hello All,
>
> Did anyone have experience putting electronics, especially Moxa NPort
> 5110[1] and IFW Intelligent Filter Wheel[2], inside accelerator(Linac,
> Booster, Storage Ring) tunnel? Any shielding required?
Don't know about the devices you listed, but I remember we had Heidenhain
position measurement systems near the vacuum chamber and these things became
very non-linear after a few weeks (i.e. they still gave back positions but
completely wrong ones).
Cheers
Ben
________________________________
Helmholtz-Zentrum Berlin für Materialien und Energie GmbH
Mitglied der Hermann von Helmholtz-Gemeinschaft Deutscher Forschungszentren e.V.
Aufsichtsrat: Vorsitzender Prof. Dr. Dr. h.c. mult. Joachim Treusch, stv. Vorsitzende Dr. Beatrix Vierkorn-Rudolph
Geschäftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Dr. Ulrich Breuer
Sitz Berlin, AG Charlottenburg, 89 HRB 5583
Postadresse:
Hahn-Meitner-Platz 1
D-14109 Berlin
http://www.helmholtz-berlin.de
- References:
- radiation damage to electronics inside accelerator tunnel? Hu, Yong
- Navigate by Date:
- Prev:
Re: Sequencer Preprocessor Build Rules Benjamin Franksen
- Next:
RE: AreaDetector: Prosilica camera on different subnet? Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
<2011>
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: radiation damage to electronics inside accelerator tunnel? Richard Farnsworth
- Next:
RE: radiation damage to electronics inside accelerator tunnel? austen.rose
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
<2011>
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|