1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: sscan and averaging [SEC=UNCLASSIFIED]
From: "LYNCH, Damien" <[email protected]>
To: <[email protected]>
Date: Fri, 14 Jan 2011 12:00:44 +1100

Hi,

 

We have a sscan record setup to allow operators to scan over a sample in an ion source. Currently the data read at each scan position is whatever the detector is reading at that instant. We would like to acquire several times at each position and take the average. What is the best way of doing this? Should I set up a multidimensional scan and set the ACQM field in the inner sscan record to ACCUMULATE and perform the averaging elsewhere after the scan is finished?

 

Thanks,

Damien Lynch

Accelerator IT Systems Engineer

Institute of Environmental Research

Australian Nuclear Science and Technology Organisation

Locked Bag 2001 Kirrawee DC NSW 2232

 

 

Important: This transmission is intended only for the use of the addressee. It is confidential and may contain privileged information or copyright material. If you are not the intended recipient, any use or further disclosure of this communication is strictly forbidden. If you have received this transmission in error, please notify me immediately by telephone and delete all copies of this transmission as well as any attachments.

 


Replies:
Re: sscan and averaging [SEC=UNCLASSIFIED] Tim Mooney

Navigate by Date:
Prev: Re: Access to records from subroutines during iocInit Rod Nussbaumer
Next: Re: sscan and averaging [SEC=UNCLASSIFIED] Tim Mooney
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Access to records from subroutines during iocInit Rod Nussbaumer
Next: Re: sscan and averaging [SEC=UNCLASSIFIED] Tim Mooney
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·