1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: labview w/ CA
From: "Dale L. Brewe" <[email protected]>
To: Paul Sichta <[email protected]>
Cc: EPICS Tech-Talk <[email protected]>
Date: Tue, 21 Jul 2009 16:00:26 -0500
I've also been using SCA with call library function nodes in our labview CA clients for quite some time, and it has worked very well for me. Unfortunately I haven't been able to get the version based on 3.14 to work properly w/ my clients. I believe there is a version based on 3.14 using ActiveX controls but I have not tried using it to any significant extent.
dale

Paul Sichta wrote:
Wesley,
I suppose you've googled and searched tech-talk.

I've been using a Simple Channel Access (SCA) package with LabVIEW support for years. It works but it has problems when an IOC is rebooted, so I'm all for for a better solution but it has perennially been a low priority.

Several methods are described at GSI:
http://wiki.gsi.de/cgi-bin/view/Epics/ConnectingLabVIEWandEPICS

National Instruments offers two solutions. The first is to buy LabVIEW and the add-on Data Supervisory & Control Package, which has EPICS CA support built-in. The second method which I haven't tried doesn't require the DSC and is described at
http://zone.ni.com/devzone/cda/tut/p/id/7987

-ps

On 07/20/2009 03:06 PM Wesley Moore wrote:
tech-talkers,
Yes I know this has been done, but what's the difficulty in setting this up? What is the preferred method and has the experience been good or bad? It seems like the decision to support this is based on extent of it's usage.

Thanks for any comments,
Wesley



--
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 Dale L. Brewe
 PNC/XOR Argonne National Laboratory

 ph: 630 252 0582         fax: 630 252 0580
 Mail:
 Argonne National Laboratory
 Bldg 435E sector 20
 9700 S. Cass Ave.
 Argonne, IL 60439
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

References:
labview w/ CA Wesley Moore
Re: labview w/ CA Paul Sichta

Navigate by Date:
Prev: Re: cainfo does display host info Ralph Lange
Next: Re: labview w/ CA Jeffrey Holt
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: labview w/ CA Paul Sichta
Next: Re: labview w/ CA Jeffrey Holt
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 31 Jan 2014 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·