1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: Problems using the sscan record
From: "Mark Rivers" <[email protected]>
To: "???" <[email protected]>, <[email protected]>
Date: Mon, 20 Apr 2009 08:25:05 -0500
It sounds like some task may be crashing in the IOC.
 
Since commands like dbl are working, you should do command like the following:
 
i
checkStack
mbufShow
 
You need to figure out if a task has stopped, if the network stack is not working, etc.
 
Can you ping the IOC when that happens?
 
Mark

 
________________________________

From: [email protected] on behalf of ???
Sent: Sun 4/19/2009 11:41 PM
To: [email protected]
Subject: Problems using the sscan record



Hi all,

 

We have some problem in using sscan records with one motor as one positioner and one ADC value from the detector.

Hardware: VME+MVME5500+MAXv-8000

Software: EPICS base3.14.8+MotorR6-2-2+Sscan from synApps5_2 + (some transform records)

The problem happens frequently when the scan is processing . When it happens:

1. All the PVs on the EDM interface are connected, but no motor (residing in this IOC) has any response to the new setting value of its Motor.DVAL. It seems the IOC doesn't accept command from OPI any more;

2. The commands like 'dbl' are still working normally on the minicom console;

3. The network between OPI and IOC is ok;

4. When restart the IOC by typing the 'reboot' command on the minicom console, the IOC can't be recovered normally.

5. The IOC have to be restarted by powering off and on.

 

We also tried to split sscan to a PC/Linux/IOC, the problems still appear.

 

Any suggestion and idea are welcomed.

 

Zhaohong

 

 

============================================
ZhaoHong Zhang
Beamline control group Dept. of Beamline Engineering 
Shanghai Synchrotron Radiation Facility(SSRF)
Shanghai Institute of Applied Physics
Chinese Academy of Sciences
239 Rd.Zhangheng,Pudong,Shanghai 201203
China               
Tel: 021-33933238                     
Email: [email protected] <mailto:[email protected]>                   
=============================================

 



Replies:
答复: Problems using the sscan record 张招红
References:
Problems using the sscan record 张招红

Navigate by Date:
Prev: Motor record compilation error under win32-x86 Wang Xiaoqiang
Next: Re: Motor record compilation error under win32-x86 Ron Sluiter
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Problems using the sscan record 张招红
Next: 答复: Problems using the sscan record 张招红
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 31 Jan 2014 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·