Hello Jerico,
It should be sufficient to replace the drvAsynSerialPortConfigure like in your
startup script with a drvAsynIPPortConfigure line.
If the device uses the vxi11 protocol ("GPIB over ethernet") use a
vxi11Configure line instead.
Dirk
Tagle, Jerico wrote:
Greetings All,
My name is Jerico Tagle and I work at SLAC National Accelerator Labaratories in Menlo Park, CA. We have successfully communicated with the Genesys 300-17 via RS232 on EPICS (Thanks to Mr Dennis Armstrong @ PSI) and would like to communicate with it via LAN. If you have existing drivers for the Genesys power supplies via LAN, can you please send me a copy? My forte is Power Electronics and I am attempting to learn EPICS to control our power supplies for the future.
Thnks For Your Time!
Jerico Tagle
--
Dr. Dirk Zimoch
Paul Scherrer Institut, WBGB/006
5232 Villigen PSI, Switzerland
Phone +41 56 310 5182
- Replies:
- Re: Genesys Power Suppy LAN driver Burkhard Kolb
- References:
- Genesys Power Suppy LAN driver Tagle, Jerico
- Navigate by Date:
- Prev:
Genesys Power Suppy LAN driver Tagle, Jerico
- Next:
EPICS driver for vacuum devices Xu, Huijuan
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
<2009>
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Genesys Power Suppy LAN driver Tagle, Jerico
- Next:
Re: Genesys Power Suppy LAN driver Burkhard Kolb
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
<2009>
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|