1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Help with streamDevice parsing HTML
From: Dirk Zimoch <[email protected]>
To: Rod Nussbaumer <[email protected]>
Cc: [email protected]
Date: Thu, 05 Mar 2009 14:42:50 +0100
There was a mistake in my previous mail. You must specify the field in the redirections (usually VAL).

    in "%*/Measure\(PPM\):/%f"
       "%*/Sample flow\(CC\):/%(\$1:FLOW.VAL)f"
       "%*/Scale:/%(\$1:SCALE.VAL)s"
       "%*/System status:/%(\$1:STATUS.VAL)s";

Dirk

--
Dr. Dirk Zimoch
Paul Scherrer Institut, WBGB/006
5232 Villigen PSI, Switzerland
Phone +41 56 310 5182

Replies:
Re: Help with streamDevice parsing HTML Rod Nussbaumer
References:
Help with streamDevice parsing HTML Rod Nussbaumer

Navigate by Date:
Prev: Re: Help with streamDevice parsing HTML Dirk Zimoch
Next: Re: Help with streamDevice parsing HTML Dirk Zimoch
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Help with streamDevice parsing HTML Dirk Zimoch
Next: Re: Help with streamDevice parsing HTML Rod Nussbaumer
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 31 Jan 2014 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·