StreamDevice version 2.4 is now available at http://epics.web.psi.ch/software/streamdevice/ This version is compatible with asyn 4.10 and base 3.14.10. Some issues with "I/O Intr" have been fixed. The most severe problem was a stack overflow on some systems with fixed small stack sizes (vxWorks, RTEMS) when multi-lime input was received. A signed long conversion problem on 64 bit machines has been fixed for ai, ao, longin, longout records. New formats (some have already been available as patches) %R -- raw float/double %0r -- raw unsigned integer %m -- a strange mantissa-exponent format without . or e %#b and %#B -- little endian bit order for %b and %B Thanks to all bug reporters. Dirk -- Dr. Dirk Zimoch Paul Scherrer Institut, WBGB/006 5232 Villigen PSI, Switzerland Phone +41 56 310 5182
| ||||||||||||||