1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  <20082009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  <20082009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: multiple levels of substitution in msi
From: John Dobbins <[email protected]>
To: EPICS Tech-Talk <[email protected]>
Date: Tue, 08 Jan 2008 11:13:27 -0500
Is there a way to get MSI to deal with multiple levels of substitution?

I have several targets that conform to a common pattern. Within each target the same block of records appears multiple times. So ideally I'd like to have a template for the target database which in turn calls a template for the block of records.

John Dobbins
Lab for Elementary Particle Physics
Cornell University

Replies:
RE: multiple levels of substitution in msi Allison, Stephanie

Navigate by Date:
Prev: Re: gateway throttling events? Gasper Jansa
Next: Soft IOC VME access Robert Ellis
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  <20082009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: gateway throttling events? Janet Anderson
Next: RE: multiple levels of substitution in msi Allison, Stephanie
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  <20082009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024