Subject: Re: SIMM mode for mbbiDirect record
From: Kay-Uwe Kasemir <kasemirk@ornl.gov>
To: tech talk <tech-talk@aps.anl.gov>
Date: Thu, 07 Dec 2006 17:18:44 -0500
Here's what seems to work in 'diff' format:

base/3.14.8.2/src/rec/mbbiDirectRecord.c,v
267c267
<       if (pmbbiDirect->simm == menuSimmRAW){
---
>       else if (pmbbiDirect->simm == menuSimmRAW){




References:
SIMM mode for mbbiDirect record Vladimir Sirotenko
Re: SIMM mode for mbbiDirect record Kay-Uwe Kasemir