Experimental Physics and
| |||||||||||||||
|
It looks like SIMM mode for mbbiDirect records does not work in epics 3.14 generating "Invalid" severity state. Simple setup is shown below: record(longin,"CTL_VS/SET") { field(DTYP, "Soft Channel") field(SCAN, "1 second") field(FLNK, "CTL_VS/MBBI") field(VAL,"1") field(PINI,"YES") } record(mbbiDirect,"CTL_VS/MBBI") { field(DTYP, "Raw Soft Channel") field(INP, "2") field(SCAN, "Passive") field(NOBT, "16") field(SHFT, "0") field(SIMM, "YES") field(SIOL, "CTL_VS/SET") field(FLNK, "CTL_VS/LONGIN") } record(longin,"CTL_VS/LONGIN") { field(DTYP, "Soft Channel") field(INP, "3") field(SCAN, "Passive") field(SIMM, "YES") field(SIOL, "CTL_VS/SET") } The record CTL_VS/MBBI is always in "Invalid" state while longin CTL_VS/LONGIN is ok Did anyone see it? Vladimir
| ||||||||||||||