1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: Bugs in 3.14.5
From: "Mark Rivers" <[email protected]>
To: "Kate Feng" <[email protected]>, "Eric Norum" <[email protected]>
Cc: <[email protected]>
Date: Fri, 4 Jun 2004 18:48:28 -0500
Kate wrote:

> We were able to  load eight motor cards in one crate running 
> 3.13.x vxWorks.
> I guess a better question is :did anyone load eight OMS58 motor cards
> in one crate running 3.14.x /vxWorks ?

I don't know if you are still interested in this ...
I am running a crate with 9 OMS58 cards, EPICS 3.14.6beta, vxWorks
5.4.2, no problems.  It also worked fine with EPICS 3.14.4.

Mark


Navigate by Date:
Prev: Question on transition modules Chestnut, Ronald P.
Next: RE: Question on transition modules Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Bugs in 3.14.5 (recall) Kate Feng
Next: EPICS Base Release 3.14.6 Andrew Johnson
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  <20042005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 10 Aug 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·