Motor Record users,
There is a problem with the Oregon Micro Systems (OMS)
VX2-006 ver 1.04 motor controller boards. The interrupt
control register is not cleared when the VX2 receives a
SYSRESET. This results in an IOC crash at boot-up if more
than one VX2 controller board is configured in the same
VME crate.
OMS has been notified and is working on the problem; but to
date, it has not been resolved. I will post a notice here when
it is resolved.
Regards,
Ron Sluiter
- Replies:
- OMS VX2-006 problem resolved Ronald L. Sluiter