1994  1995  1996  1997  1998  1999  2000  2001  <20022003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  <20022003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: CA error
From: john sinclair <[email protected]>
To: Jeff Hill <[email protected]>
Cc: "'tech talk'" <[email protected]>
Date: Tue, 29 Oct 2002 13:23:28 -0500 (EST)
My mistake, the error is ECA_DISCONN (which makes more sense)
and not ECA_ANACHRONISM (I shifted the value twice instead
of 3 times).

And, no, I'm not calling CA from a multi-threaded application.

John


On Tue, 29 Oct 2002, Jeff Hill wrote:

> 
> John,
> 
> >   examine args.status
> >
> >   // status here is sometimes ECA_ANACHRONISM
> > Has this always been possible?
> 
> I think you are asking if CA will set the status
> field in the event_handler_args structure to
> ECA_ANACHRONISM. The answer is no. I searched
> all of the source code in the latest versions of
> R3.13 and R3.14 and ECA_ANACHRONISM is returned
> only when you call a very old CA interface from
> R3.11 or probably earlier that is no-longer
> supported.
> 
> Are you calling CA from a multi-threaded
> application?
> 
> Jeff
> 
> > -----Original Message-----
> > From: john sinclair [mailto:[email protected]]
> > Sent: Tuesday, October 29, 2002 10:48 AM
> > To: tech talk
> > Subject: CA error
> >
> > One stress test I have applied to edm is performing a moderately rapid
> > succession of connects/disconnects via a channel access server.
> >
> > I have recently noticed one problem.
> >
> > The logical code structure is shown below:
> >
> >
> >
> > global needInit
> >
> > ==========================
> >
> > main routine:
> >
> > needInit = false
> > search_and_connect
> >
> > do {
> >   pend io, event
> >   if ( needInit ) {  // needInit is set in the connect callback
> >     ca_get_callback(...)
> >     needInit = false
> >   }
> > } until all outstanding io is complete
> >
> > ===========================
> >
> > connect_callback function (...) {
> >
> >   if ( pv is connected ) {
> >     needInit = true
> >   }
> >   else {
> >     needInit = false
> >   }
> >
> > }
> >
> > ===========================
> >
> > get_callback function (
> >   struct event_handler_args args
> > ) {
> >
> >   examine args.status
> >
> >   // status here is sometimes ECA_ANACHRONISM
> >   // and args.dbr is NULL
> >
> > }
> >
> >
> >
> > Has this always been possible? I'm sure I get the connect callback
> > before
> > the get callback (by examining other data that gets set in the connect
> > callback {not shown in above simplified example}).
> >
> > John Sinclair
> > [email protected]
> > Oak Ridge National Lab
> > 865-576-6362   865-574-1268 (fax)
> 
> 

John Sinclair
[email protected]
Oak Ridge National Lab
865-576-6362   865-574-1268 (fax)


Replies:
RE: CA error Jeff Hill
References:
RE: CA error Jeff Hill

Navigate by Date:
Prev: RE: CA error Jeff Hill
Next: Simatic PLCs Rolf Keitel
Index: 1994  1995  1996  1997  1998  1999  2000  2001  <20022003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: CA error Jeff Hill
Next: RE: CA error Jeff Hill