Hi,
I'm porting a record support routine from EPICS 3.12.3 to 3.13.4 and
found calls to the following routines that are no longer supported:
status = recGblPutFastLink (&(pmr->dstl), (void *) pmr,
&(pmr->dsta));
status = recGblInitFastInLink (&(pmr->dbgl),(void *) pmr,
DBR_ENUM, "DBUG")
status = recGblInitFastOutLink (&(pmr->dstl),(void *) pmr,
DBR_LONG, "DSTA");
DSTL and DBGL are an output link and input link respectively. Can
someone give me a hint on what are the routines I'm supposed to use now
and how the calling sequence should look like?
Thank you,
Pedro Gigoux
Gemini Observatory
- Replies:
- Re: porting record to 3.13.4 Marty Kraimer
- porting record to 3.13.4 (part 2) Pedro Gigoux
- Re: porting record to 3.13.4 Andy Foster
- Navigate by Date:
- Prev:
RE: EPICS R3.13.4 Build question??? Jeff Hill
- Next:
Re: porting record to 3.13.4 Marty Kraimer