1994  1995  1996  1997  1998  <19992000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  <19992000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: new sca3.dll
From: "Dale L. Brewe" <[email protected]>
To: "catimossi" <[email protected]>
Cc: [email protected]
Date: Fri, 16 Apr 1999 15:39:57 -0500
Chris
Thanks for the update. It seems to work for the most part. However, there
is something going on that I don't understand, but that is clearly related
to the new sca3.dll. I have a dynamically loaded subvi built into an
executable w/ the application builder, that initially connects to 140-150
pvs by individual cache_getbyname() calls (I'm aware this isn't the fastest
way, but it's convenient the way the rest of my vi is structured). With the
new sca3.dll, I consistently get an error return code 852482 for several
pvs initially (which I believe translates to 13<<16, SCA_CANNOT_GET;2<<8
SCA_NEVER_CONNECTED; 2<<0 SCA_NO_VALUE). In addition, I get a message from
LabVIEW (v5.1) that "Memory is full. Stopping vi ...". If I restart the
subvi after it quits abnormally, everything seems ok - no error codes and I
get the values ok! Curiously, I don't have this problem on the NT Server in
our network. It does occur on every one of the three NT WKS machines I've
tried (each with more available RAM than the Server). I'm wildly
speculating that you increased some internal data structure and I'm now
running into an internal NT limit that's different in NT WKS and Server. I
was wondering if you could comment on whether this has any basis in
reality, and if so, have any suggestion as to what parameter I might play
with. I tried changing the Server service on the Server machine to match
the NTWKS defaults, but with no change.
Dale
At 11:59 AM 4/15/99 , you wrote:
>Dale,
>
>Loren and I fixed the problem with slow connects for sca3.dll.
>There's a new sca3.dll posted on ftp://csg.lbl.gov/pub/als/epics/win32/sca3/
>Let me know if there's any problems and thanks for the feedback.
>
>Chris
>
>
>
>
>
>

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 Dale L. Brewe     PNC-CAT/U. of Washington
 ph: 630 252 0582         fax: 630 252 0580
 Mail:
 APS/Argonne National Laboratory
 Bldg 435E sector 20
 9700 S. Cass Ave.
 Argonne, IL 60439
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

References:
new sca3.dll catimossi

Navigate by Date:
Prev: Heidenhain IK320 driver Till Straumann
Next: Acquisition under EPICS GOURNAY Jean-François DAPNIA
Index: 1994  1995  1996  1997  1998  <19992000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: new sca3.dll catimossi
Next: Heidenhain IK320 driver Till Straumann
Index: 1994  1995  1996  1997  1998  <19992000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 10 Aug 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·