1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Koyo PLC Ethernet modules
From: John Quintana <[email protected]>
To: [email protected]
Cc: [email protected]
Date: Sat, 18 Apr 1998 13:34:56 -0500 (CDT)
For those of you using Koyo PLC's. --
I called PLC Direct on Friday and they told me that they are now
shipping the H2-ENET and H4-ENET modules for the 205 and 405
PLC systems.  These are ethernet communication modules for each
family of PLC's.  Price is $299 per module.  They also have the
Ethernet Board Controller modules for the 205 (I didn't ask about
the 405 series), so you can easily extend your PLC system onto
a 10 Base T ethernet or talk to your existing PLC's via ethernet.
These modules are produced by Host Engineering and I have ported
their communications code over to Linux.  I
believe that there is still a big-endian/little-endian issue still for
other machines, but if you are running on a PC type system, you
can easily talk to your PLC's.  

We don't run EPICs on our beamline at the APS, so we really have no
interest in coming up with an EPICS driver for these systems.  However,
if anyone wants to take a crack at this, I can send you the source code
and try to find out if anyone has dealt with the endian issues.  It seems
to me that it would make a nice addition to the EPICS arsenal since PLC
Direct's products are very cost effective and can really extend the notion
of distributed control.   

---
John Quintana                              Phone:630-252-0223
Northwestern University                    FAX: 630-252-0226      
DND-CAT                                    email: [email protected]
APS/ANL Building 432/A003
9700 South Cass Avenue
Argonne, IL 60439


Navigate by Date:
Prev: Re: Medm error message... Chris Larrieu
Next: symbol for calcout record Benjamin Franksen
Index: 1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Another Linux/medm problem... madre
Next: symbol for calcout record Benjamin Franksen
Index: 1994  1995  1996  1997  <19981999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 10 Aug 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·