> From [email protected] Fri Mar 28 06:20:45 1997
> Subject: Re: Rebooting an IOC
> Date: Fri, 28 Mar 1997 09:27:47 -0700
>
> At APS they used specialized hardware to provide remote access to the VME
> system reset via a terminal server (via a special character sequence
> recognized by this hardware).
>
> Jeff
>
At Keck we use a Keithley Metrabyte serial to digital module (~$200)
connected to a terminal server. The output signals are connected directly
to the reset signals on VME buses. This provides a means of resetting a
subset of upto 8 systems per module. Each module can be set to have a
unique address so multiple modules can exist on a single serial line.
We find this very handy as we often need to reset systems when nobody
is at the telescopes (ie. during inclement weather or early morning).
Allan