FYI -- this was in a note that I got from Motorola recently:
1. AUTO SCON Problems on MVME160x, MVME177, and MVME162
The MVME1600, MVME177, and MVME152-5xx VMEmodules have jumpers
to enable the Automatic System Controller (AUTO SCON) feature.
This feature is *NOT* functioning properly and, until further
notice, should not be used. The boards should be jumpered
for either SYSTEM CONTROLLER or NOT SYSTEM CONTROLLER depending
on the VME chassis configuration.
--John Winans