Subject: new caEventRate diagnostic
From: "Jeff Hill" <[email protected]>
To: <[email protected]>
Date: Thu, 9 Jan 2003 10:41:14 -0700
Hi Ken,

I changed caEventRate so that it has a 1:1 ratio for channels to
monitors in order to better reflect reality. I committed this version to
CVS. This caused the server's CPU to saturate. This also caused the
maximum event rate from the gateway to drop down to 250k events per sec.

Connecting to CA Channel "joh:jane" 40000 times. done. Subscribing 40000
times. done. Waiting for initial value events. done. CA Event Rate (Hz):
current 194227 mean 194227 std dev 0.00101583 CA Event Rate (Hz):
current 239705 mean 216966 std dev 22738.8 CA Event Rate (Hz): current
256943 mean 230292 std dev 26454.6 CA Event Rate (Hz): current 254222
mean 236275 std dev 25144.8 CA Event Rate (Hz): current 253042 mean
239628 std dev 23469 CA Event Rate (Hz): current 253130 mean 241878 std
dev 22007.1 CA Event Rate (Hz): current 253139 mean 243487 std dev
20752.2 CA Event Rate (Hz): current 252582 mean 244624 std dev 19643.5

This seems to indicate that the locking overhead is significant.

Jeff
__________________________________________________________
Jeff Hill                     Internet     [email protected]
LANL MS H820                  Voice        505 665 1831
Los Alamos NM 87545 USA       FAX          505 665 5107





Navigate by Date:
Prev: R3.14 portable ca server monitor throughput performance has been improved Jeff Hill
Next: RE: MEDM 3.13 vs. 3.14 Jeff Hill
Index: 2002  <20032004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: R3.14 portable ca server monitor throughput performance has been improved Jeff Hill
Next: RE: MEDM 3.13 vs. 3.14 Jeff Hill
Index: 2002  <20032004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 02 Feb 2012 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·