Capabilities
Development, analyses, specification, fabrication, installation, and performance evaluation of x-ray optical elements including:
Many of these optical components are subjected to extremely high heat load of the incident x-ray beam and as such are actively cooled.
X-ray beam power and heat flux can be as high as 10 kW and 150 W/mm2, respectively, and are expected to increase.
Design of a cooled substrate with minimal surface degradation due to the thermal load is a major component of our activity.
Contact: Dr. A. Khounsary, amk@aps.anl.gov
Update:
August 4, 2005
|