1-ID: Sector 1, Insertion Device Beamline

Responsible Scientists

Scientific Programs

  • High-energy x-ray optics development
  • Powder and pair-distribution function measurements
  • Single-grain studies
  • Coupled SAXS/WAXS studies

Source Characteristics

Insertion device: APS Undulator A
No. of Poles 72
Undulator Period 3.3 cm
Device Length 2.4 m
Minimum Gap 11 mm

Optical Components

Component
Distance from Center of ID
Comment
Front end separation window
24.8 m
500 microns Be. No additional filters.
Filters
25.7 m
Two banks of graphite of various thicknesses up to 2 mm.
White beam slits (L1)
26.9 m
 
Kohzu double crystal monochromator.
29.8 m
LN 2 Cooling. With Si (111) 6 to 19 keV. With Si (311) 9 to 48 keV. Scans energy very well. Resolution dE/E~1e-4
High energy monochromator
34.0 m
LN 2 Cooling. Energy range > 40 keV. Does not scan energy well. Resolution dE/E ~ 1e-3
Post-monochromator optics
34-57 m
See the high-energy optics section of this website

 

Beamline Configuration (click here for a beamline schematic)

1-ID-A is a first optics enclosure (FOE) which houses the front-end separation window, white-beam filter, white-beam slits, Kohzu double-crystal monochromator, white-beam stop, and monochromatic-beam shutter. The equipment in this station is permanent and, generally, does not change from experiment to experiment.

1-ID-B is an experimental station that can take either white beam or monochromatic beam from 1-ID-A. It can be used for experiments, but due to its relatively small size, it is most often used to condition the x-ray prior to transmission to 1-ID-C. The high-energy monochromator is located at the upstream end of 1-ID-B. The center of the 1-ID-B station is 36 m from the center of the ID straight section. Recent work has focused on conditioning the x-ray beam (focusing/reducing energy width) after the high-energy monochromator.

1-ID-C is the work horse experimental station on the 1-ID beamline. The center of this station is 60 m from the center of the ID straight section. The station is 7 m is length (along the beam path) and 4 m wide. Only monochromatic beam can be transmitted to 1-ID-C (the transport is offset 24 mm above the white beam).