The first two gas yard lights have been installed using photo-sensors. Waiting for parts to complete the remainder light installations.
Machine Stats
11/02/2005 08:00 To 11/08/2005 08:00
Delivered beam: 144.00 Hours
Mean Time between Faults: 143.57 Hours
Percent Scheduled Time: 99.70%
Faults: 1 Fault(s)
Beamline Data
Beamtime Downtime Summary by APS Groups, 10/31/2005 to 11/7/2005
DIN |
Date |
Beamline |
Status |
Duration |
Group |
Description |
Resolution |
535 |
11/06/05 |
9-BM |
Closed |
2 hr 45 min |
ASD-VAC |
P8 pressure switch inhibited shutter from operating properly. RMD #04742 filed. ASD-SI personnel notified. |
Troubleshooting determined faulty Chain B pressure switch. Switch cycled and began functioning normally. BP agreed to have the sensor checked during studies. Beamline restored to proper operations. ASD-VAC filed WR #19232 on 11/8 to replace P8 PSS chain A and B pressure switches. |
Safety
Environment management system audit to take place November 16, 2005, involving mainly AOD management.