Listing of Statistics for Run3-2009 (Created Sat Nov 07 14:05:28 CST 2009)
User periods in this interval
10/06/2009 08:00 To 10/13/2009 08:00 168.00 Hours, Delivered Beam: 159.72 Hours, 6 Fault(s), 26.62 MTBF, 95.07% of Sched. Time 10/14/2009 08:00 To 10/19/2009 08:00 120.00 Hours, Delivered Beam: 113.32 Hours, 2 Fault(s), 56.66 MTBF, 94.44% of Sched. Time 10/21/2009 08:00 To 10/27/2009 08:00 144.00 Hours, Delivered Beam: 144.00 Hours, 0 Fault(s),144.00 MTBF,100.00% of Sched. Time 10/28/2009 08:00 To 11/03/2009 08:00 145.00 Hours, Delivered Beam: 144.53 Hours, 1 Fault(s),144.53 MTBF, 99.67% of Sched. Time 11/04/2009 08:00 To 11/07/2009 14:03 78.05 Hours, Delivered Beam: 78.04 Hours, 0 Fault(s), 78.04 MTBF, 99.99% of Sched. Time
Total Amount of User Time in this interval 655.02 HoursDelivered Beam 639.61 Hours
Percentage of Scheduled Time (*) 97.65 %
Mean Time Between Faults (MTBF) 71.07 Hours
Downtime During Period 15.41 Hours
Total integrated Current During This Period 64.65 A-hr
Mean Fill Duration in Period 63.96 Hours
Faults per Day of Delivered Beam 0.34
Total Number of Faults 9
Valid fills Beginning in this Time Interval      
Fill # Start  End Duration
(min: 1.0)
Reason for Fill Termination Length of Downtime Downtime is associated with the end of a fill. The first fill of a period will have any downtime before the fill on the line above.

  0.00
# 1 10/06 08:00 To 10/06 13:18 5.31    CU steering failure[PS] 0.70 Investigation and refill
# 2 10/06 14:00 To 10/06 16:56 2.92    RF4 HVPS trip [RF] 0.44 Investigation, refill
# 3 10/06 17:22 To 10/06 19:27 2.08    PS DAC error [CTL] 5.10 2nd beam loss,IOCS37BPM failed[CTL]
# 5 10/07 00:33 To 10/08 15:46 39.23    CPU AFG malfunction[CTL] 0.38 Investigation, refill
# 6 10/08 16:09 To 10/09 14:59 22.82    S26B:Q5:PS glitch [PS] 1.29 Investigtion, swap-out supply, refill
# 7 10/09 16:16 To 10/10 06:04 13.79    RF4 Mod Anode trip[RF] 0.35 Investigation, refill
# 8 10/10 06:25 To 10/13 07:59 73.57    Int Dump: End of Period 0.00

  0.00
# 9 10/14 08:00 To 10/16 00:01 40.02    RF3 comm.problems [??] 0.54 Investigation, refill
# 10 10/16 00:33 To 10/19 01:51 73.30    RF3 HVPS problem [RF] 6.14 Investigation, waveguide switch

  0.00
# 14 10/21 08:00 To 10/27 07:59 144.00    Int Dump: End of Period 0.00

  0.00
# 15 10/28 08:00 To 11/02 09:50 122.83    420RF-PSS trip [RF] 0.47 Investigation, refill
# 16 11/02 10:18 To 11/03 07:59 21.70    Int Dump: End of Period 0.00

  0.00
# 17 11/04 08:00 To 11/07 14:02 78.04    Fill Ongoing 0.00
Top-Up Mode Statistics
Target Current Range +/- 2.0, Minimum Injector Downtime = 8.0 minutes Total
Current in Range during Scheduled Topup Time 97.26 %
Current in Range during Delivered Beam Time 99.93 %
Injector Availability 99.91 %
Period Beginning 10/06/2009 08:00
Current in Range 100.00 %
Injector Availability 100.00 %
Period Beginning 10/14/2009 08:00
Current in Range 100.00 %
Injector Availability 100.00 %
Period Beginning 10/21/2009 08:00
Current in Range 100.00 %
Injector Availability 100.00 %
Period Beginning 10/28/2009 08:00
Current in Range 99.73 %
Injector Availability 99.65 %
Out of Range at: 10/29/2009 20:42:00 to 10/29/2009 20:50:32 : 8.53 minutes
Injector downtime:10/29/2009 20:37:04 to 10/29/2009 20:50:28 : 13.40 minutes
Out of Range at: 10/31/2009 10:24:16 to 10/31/2009 10:38:48 : 14.53 minutes
Injector downtime:10/31/2009 10:19:20 to 10/31/2009 10:36:40 : 17.33 minutes
The information on this page is automatically generated and may contain errors. An official operations statistics page will be posted at the end of each user period.