APS Running Statistics; FY98 to Present
Fiscal Year Scheduled User   Hours User Beam Available hours User beam Availability (%) Total Faults Mean Time to Recovery Faults Per Day of Delivered Beam Delivered Integrated Current    (A-hr) Hours of Top-up Scheduled Top-up Injector Availability MTBF
1998 4465.9 4163.2 93.22% 124 2.4 0.71 321.2 0.0 N/A 33.6
1999 5053.4 4767.7 94.35% 176 1.6 0.89 380.7 0.0 N/A 27.1
2000 5047.2 4723.8 93.59% 160 2.0 0.81 390.2 0.0 N/A 29.5
2001 5000.3 4788.7 95.77% 188 1.1 0.94 409.8 1032.0 96.1% 25.5
2002 4999.0 4855.4 97.13% 147 1.0 0.73 469.1 3680.0 94.9% 33.0
2003 4912.0 4772.5 97.16% 107 1.3 0.54 467.6 3592.0 97.6% 44.6
2004 5225.0 5112.5 97.85% 89 1.3 0.42 509.9 3865.6 97.9% 57.4
2005 5001.5 4931.0 98.59% 49 1.4 0.24 433.7 3976.5 98.5% 100.6
2006 5000.0 4875.5 97.51% 57 2.2 0.28 488.9 3928.0 97.3% 85.5
2007 4832.0 4750.8 98.32% 49 1.7 0.25 476.2 3816.0 98.4% 97.0
2008 4588.1 4478.8 97.62% 49 2.2 0.26 449.4 3584.0 96.6% 91.4
2009 5000.0 4883.4 97.67% 63 1.9 0.31 490.0 3736.0 97.9% 77.5
2010 5000.0 4924.8 98.50% 49 1.5 0.24 493.5 4040 98.8% 100.5
2011 5000.0 4906.1 98.12% 56 1.7 0.27 489.9 3832 97.8% 87.6
2012 5000.0 4969.4 99.39% 25 1.2 0.12 497.3 3952 98.4% 198.8
2013 5000.0 4895.0 97.90% 49 2.1 0.24 487.5 3928 96.7% 99.9
2014 1545.0 1511.5 97.83% 15 2.2 0.24 151.7 1264 97.8% 100.8
Total 64124.5 62028.1 96.73% 1307 1.6 0.51 5780.3 35250.1 97.2% 47.5