- There was a bug in the
ECOL element when the length was nonzero and the offset (DX or DY) was nonzero.
This was fixed.
- To avoid numerical problems, synchrotron radiation is now disabled automatically for
KSEXT elements shorter than 1
m
when performing beam moments calculations with radiation.
- In some cases, the matrix for the
MATR element would not get loaded prior to tracking, resulting in a crash. This was fixed.
- A bug was fixed in post-adjustment of synchrotron radiation losses in the
CSRCSBEND element, which made extremely small errors
in the results This was reported by K. Amyx (Tech-X).