RADIATION SAFETY DEVICE LIST (Full Version)  
        PSS Type 1 PSS Type 3 PSS Type 5  
Interface Types:       PSS Type 2 PSS Type 4    
     
               
Names:             By Machine Consequence Level Device/System Location(s) Device/System Partition Description Device/ System Ownership Associated Work Flow Procedures Comments  
ACCELERATOR              
Linac/PAR:              
Linac Laser Gate Valve Shutter High   ACIS Interface Yes.  RSS Boundary = Gate valve, position switches & equipment RSS path. ASD/MEG ASD/VTG  ASD/SIG      
LINAC Laser Enable Power Supply High   ACIS Interface Yes.  RSS Boundary = Monitor and control power to the laser via relay contacts. ASD      
RF Gun 1 Kicker Supply (RG1:KIK) Med. * L1 Section of Linac ACIS Interface Type - 1 RSS Boundary - Control relays and wiring associated with ACIS. ASD/PSG The Check out of RG1:KIK after ACIS components have been repaired. 2 Only for ACIS inside of equipment.1  *Defined as medium level not high because it is part of redundant RSS pair.    
RF Gun 2 Kicker Supply (RG2:KIK) Med. * L1 Section of Linac ACIS Interface Type - 1  RSS Boundary - Control relays and wiring associated with ACIS. ASD/PSG The Check out of RG2:KIK after ACIS components have been repaired. 2 Only for ACIS inside of equipment.1  *Defined as medium level not high because it is part of redundant RSS pair.    
L1 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1 RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L1 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupts external interlocks in both EMI HV power supplies and shuts them off.  ASD/RFG                                   ASD/SIG The Check out of RF 1 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           
L2 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1 RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L2 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupts external interlocks in both EMI HV power supplies and shuts them off.  ASD/RFG                                   ASD/SIG The Check out of RF 2 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           
L3 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1 RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L3 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupts external interlocks in both EMI HV power supplies and shuts them off.  ASD/RFG                                   ASD/SIG The Check out of RF 3 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           
L4 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1  RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L4 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupts external interlocks in both EMI HV power supplies and shuts them off.  ASD/RFG                                   ASD/SIG The Check out of RF 4 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           
L5 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1 RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L5 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupt external interlocks in both EMI HV power supplies and shuts them off  ASD/RFG                                   ASD/SIG The Check out of RF 5 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           
** L6 ACIS/Modulator Interface Med. *   ACIS Interface Type - 1 RSS Boundary =  Consists of an interface chassis, junction box and wiring which perform the following functions: [1] routes ACIS permit contact closures to the L6 both upper and lower EMI HVPS’s utilizing an external contact interlock input to the HVPS that involves relays K11 and K12, connectors P10 and P11 in the modulator’s junction box, and external interlock inputs of the EMI supplies; [2] sends the ACIS status to EPICS through the junction box connector P12. The interface chassis provides +15 VDC through connector P24. If ACIS is not in the linac “Beam Permit” mode, opened contacts in the modulator’s ACIS chassis interrupt external interlocks in both EMI HV power supplies and shuts them off  ASD/RFG                                   ASD/SIG The Check out of RF 6 Amplifier. 2 1                                  *Defined as medium level not high because it is part of redundant RSS pair.                           ** L6 is not interfaced with ACIS.                   
PAR dipole Power Supply (P:BM) Med. * Bldg. 411-B105 ACIS Interface Yes. RSS Boundary = Main Power contactor and wiring and control relays associated with ACIS.  This MAY include the ACIS box outside the equipment. ASD/PSG The Check out of P:BM after ACIS components have been repaired. 2 Only for ACIS inside of equipment, & the ACIS box outside of equip. 1  *Defined as medium level not high because it is part of redundant RSS pair.   
Injector Test Stand Wave Guide Switch Interface High Sw. #5 is located in the linac tunnel, gun end. Sw. #6 is located in the Injector Test Stand.  ACIS Interface Yes. RSS Boundary = Work on the S-band switches and associated cabling to and including the cable junction boxes. ASD/RFG   ASD/SIG 3 Wave-guide switches numbered 5 and 6 are installed in the linac wave-guide that connects to the RF Gun Test Room.  
L1 ACIS/BESOCM/    Modulator Interface High L1 Section of the Klystron Gallery ACIS Interface Yes.  RSS Boundary = Consists of the Interface chassis (board AA, local/remote control board, connector P15 and wiring), the thyratron drive chassis (TTC), high-voltage coaxial cable between theTTC and the thyratron box, and a fiber optic cable between the BESOCM triggering chassis and the modulator interface chassis. The interface performs the following function: routes optical-analog-high-voltage triggering signal to the L1 thyratron switch. If ACIS decides to stop the modulator from triggering, the BESOCM disables its output, no optical triggering signal is received by board AA of the modulator interface chassis, and the thyratron does not fire. ASD/RFG      
L3 ACIS/BESOCM/    Modulator Interface High L3 Section of the Klystron Gallery ACIS Interface Yes.  RSS Boundary = Consists of the Interface chassis (board AA, local/remote control board, connector P15 and wiring), the thyratron drive chassis (TTC), high-voltage coaxial cable between theTTC and the thyratron box, and a fiber optic cable between the BESOCM triggering chassis and the modulator interface chassis. The interface performs the following function: routes optical-analog-high-voltage triggering signal to the L3 thyratron switch. If ACIS decides to stop the modulator from triggering, the BESOCM disables its output, no optical triggering signal is received by board AA of the modulator interface chassis, and the thyratron does not fire. ASD/RFG      
LINAC Besocm Trigger Steering WaveGuide Switches High Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Two WR 340 waveguide switches (WG Switches #3 and #9) that provide positive indication of which  modulator is driving an rf gun. The position of the waveguide switches is monitored by the Linac ACIS system, utilizing dedicated position indicating switches installed inside each waveguide switch. These position indicating switches provide separate contact closures to the each of the three chains of the ACIS system. The BESOCM is always triggered by the modulator pulse that is driving an rf gun.  ASD/RF 2    
LINAC BESCOM Trigger Chassis High Bldg. 412, Rm B107 ACIS Interface Type Yes. RSS Boundary = any work on the BESCOM Trigger Switch Chassis and the output fiber cables to the modulators and BESOCM devices. ASD/Controls 3 The BESOCMs must be triggered by the particular linac rf system that is supplying rf to the guns  
Linac/PAR Beam Shutoff Current Monitors High Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Beam shutoff monitors and equipment in RSS device path. Diagnostics 2 1  
L1 Trigger and Interlock Module ACIS Shutdown Chassis Med. Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Consists of a double width NIM module plus a supplementary boxed latch chassis with associated wiring which routes an ACIS permit contact closure to a dedicated relay in the L1 klystron (400 watt) rf driver amplifier that inhibits 120v ac power to the amplifier until it is energized. The NIM module also contains machine protection interlock relays that inhibit the gate to the L1 klystron (400 watt) rf driver amplifier. Receiving the rf drive gate fiber optically and distributing it coazially is another function of the NIM module.  ASD/RF 2    
L2 Trigger and Interlock Module ACIS Shutdown Chassis Med. Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Consists of a double width NIM module plus a supplementary boxed latch chassis with associated wiring which routes an ACIS permit contact closure to a dedicated relay in the L2 klystron (400 watt) rf driver amplifier that inhibits 120v ac power to the amplifier until it is energized. The NIM module also contains machine protection interlock relays that inhibit the gate to the L2 klystron (400 watt) rf driver amplifier. Receiving the rf drive gate fiber optically and distributing it coazially is another function of the NIM module.  ASD/RF 2    
L3 Trigger and Interlock Module ACIS Shutdown Chassis Med. Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Consists of a double width NIM module plus a supplementary boxed latch chassis with associated wiring which routes an ACIS permit contact closure to a dedicated relay in the L3 klystron (400 watt) rf driver amplifier that inhibits 120v ac power to the amplifier until it is energized. The NIM module also contains machine protection interlock relays that inhibit the gate to the L3 klystron (400 watt) rf driver amplifier. Receiving the rf drive gate fiber optically and distributing it coazially is another function of the NIM module.  ASD/RF 2    
L4 Trigger and Interlock Module ACIS Shutdown Chassis Med. Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Consists of a double width NIM module plus a supplementary boxed latch chassis with associated wiring which routes an ACIS permit contact closure to a dedicated relay in the L4 klystron (400 watt) rf driver amplifier that inhibits 120v ac power to the amplifier until it is energized. The NIM module also contains machine protection interlock relays that inhibit the gate to the L4 klystron (400 watt) rf driver amplifier. Receiving the rf drive gate fiber optically and distributing it coazially is another function of the NIM module.  ASD/RF 2    
L5 Trigger and Interlock Module ACIS Shutdown Chassis Med. Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = Consists of a double width NIM module plus a supplementary boxed latch chassis with associated wiring which routes an ACIS permit contact closure to a dedicated relay in the L5 klystron (400 watt) rf driver amplifier that inhibits 120v ac power to the amplifier until it is energized. The NIM module also contains machine protection interlock relays that inhibit the gate to the L5 klystron (400 watt) rf driver amplifier. Receiving the rf drive gate fiber optically and distributing it coazially is another function of the NIM module.  ASD/RF 2    
PAR RF Med.* Bldg. 412, Rm B107 ACIS Interface Yes. RSS Boundary = PAR RF and equipment in RSS device path.  Consists of an interface chassis located in building 411, room B107 and routes ACIS permit contact closures to the fundamental par tube amplifier #1 and #2 and the harmonic par tube amplifier #1 and #2. For harmonic tube amplifiers, ACIS contact closure involves relay K3 and terminal block TB3 both located inside the tube amplifier chassis and when ACIS permission is denied will put both harmonic tube #1 and #2 in stand-by mode (no high voltage).The back door of these harmonic tube amplifier chassis are also interlocked and if the door opens, the unit will go into stand-by. For fundamental tube amplifier, ACIS contact closure involves K13 and terminal block TB4 on the interlock relay chassis located inside the fundamental tube amplifier racks. When ACIS permission is denied both fundamental tube amplifier will loose high voltage. Both fundamental tube amplifiers back doors are also interlocked. ASD/RFG 2 1                                               *Defined as medium level not high because it is part of redundant RSS pair.   
ACIS - Linac to PAR Bending Magnet Interface LTP:B1 High 411 ACIS Interface Yes. RSS Boundary = Bending magnet interface and equipment in RSS path. ASD/PSG 2,3 The Linac/PAR ACIS monitors the status of the Linac to PAR Bending Magnet. 1  
L1 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
L2 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
L3 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
L4 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
L5 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
L6 Kylstron Lead Shielding Medium   ACIS Interface No.  RSS Boundary = Protection from klystron X-rays; consists of a number of lead plates, rings, etc.; is monitored by HP on a daily basis.  ASD/RFG    AOD/HP      
LACIS:  Laser Access Control Medium Laser Room (A103A) ACIS Interface No. RSS Boundary =  ASD/APG 2,3 LASER Access Control Interlock System  
Synchrotron/         BOOSTER              
PAR to Booster Triple Beam Stopper High PAR Tunnel, NW corner ACIS Interface Yes. RSS Boundary = Double radiation stopper and equipment in RSS device path. ASD/MEG  ASD/VAC 2 ACIS monitors & controls two radiation stoppers. 3  
Linac to Booster Double Radiation Stopper High PAR Tunnel, NW  ACIS Interface Yes. RSS Boundary = Double radiation stopper and equipment in RSS device path. ASD/MEG  ASD/VAC 2 ACIS monitors & controls two radiation stoppers. 3  
Booster to Ring Double Radiation Stopper High Booster Tunnel ACIS Interface Yes. RSS Boundary = Double radiation stopper and equipment in RSS device path. ASD/MEG  ASD/VAC 2 ACIS monitors & controls one radiation stopper. 3  
Booster to LEUTL Single Radiation Stopper High LEUTL Alcove in Injection side of the Booster Tunnel. ACIS Interface Yes. RSS Boundary = Double radiation stopper and equipment in RSS device path. ASD/MEG  ASD/VAC 2 ACIS monitors & controls one radiation stopper. 3  
RF 5 HV modulator and RF 5 Amplifier) Med.* 420 ACIS Interface Yes. RSS Boundary =  Consists of an interface chassis and wiring which performs the following functions: [1] routes ACIS permit contact closures to the RF5 HVPS utilitzing an external contact interlock input to the HPVS, [2] switches 120v ac power to the RF5 klystron (Kalmus) rf driver amplifier, [3] routes a contact closure from the HVPS back to the ACIS system to indicate the off/on status of the HVPS, [4] provides a contact closure to the ACIS system that indicates the on/off status of the switched 120v ac power to the klystron (Kalmus) rf driver amplifier, [5] provides contact status outputs to the EPICS control system to indicate the interface box status, and [6] provides external reset capabilities of the ACIS/RF Interface Chassis from EPICS.   ASD/RFG   *Defined as medium level not high because it is part of redundant RSS pair.    
BOOSTER Dipole Power Supply (B:BM) Med.* Bldg. 412 - West End. ACIS Interface Yes. RSS Boundary = Main power contactor and wiring and control relays associated with ACIS. This MAY include the ACIS box outside the equipment. ASD/PSG The Check out of B:BM after ACIS components have been repaired. 2,3 Only for ACIS inside of equip., & the ACIS box outside of equipment. 1  *Defined as medium level not high because it is part of redundant RSS pair.    
BOOSTER Dipole Power Supply (BTS:BX) High 420 - col#  A7   (across form the truck dock). ACIS Interface Yes. RSS Boundary = Shunt wiring and control relays associated with ACIS. This include the ACIS pannel in the realy rack. ASD/PSG The Check out of BTS:BX after ACIS components have been repaired.  Check out PS comparison circuitry if serviced by the PS Group. Check response of gap switches in magnet if serviced. Only for ACIS threshold detection, and the ACIS of equipment inside of the rack.  
Synchrotron to Storage Ring High Energy Transport Line Steering High   ACIS Interface Yes.  RSS Boundary = BX and AB steering magnet status and equipment in RSS path.   ASD/PSG Check out PS comparison circuitry if serviced by the PS Group. Check response of gap switches in magnet if serviced. The RF Area ACIS monitors the status of the steering magnets (BX and AB magnets) that direct the beam from the Synchrotron to the beam dump or to the Storage Ring.  
Storage Ring:              
BOOSTER Bypass bending magnet Power Supply (BB:BV1) Low Bldg. 412 - West End to right of the elevator. ACIS Interface Type - 0. RSS Boundary - ACIS does not monitor or control. PSG The Check out of BB:BV1 after the replacement of the supply or ACIS components have been repaired. Only for ACIS and the interface to the supply.  
BOOSTER Bypass bending magnet Power Supply (BB:BV2) Low Bldg. 412 - Outside B102 to right of the elevator. ACIS Interface Type - 0. RSS Boundary - ACIS does not monitor or control. PSG The Check out of BB:BV2 after the replacement of the supply or ACIS components have been repaired. Only for ACIS and the interface to the supply.  
RF 1 HV modulator and RF 1 Amplifier) Med.* 420 ACIS Interface Yes. RSS Boundary =  Consists of an interface chassis and wiring which performs the following functions: [1] routes ACIS permit contact closures to the RF1 UVC HVPS system utilizing the “external 3” contact interlock input which involves relay #3 on relay card #11 in the UVC control system, [2] switches 120v ac power to the RF1 klystron (Kalmus) rf driver amplifier, [3] routes a contact closure generated by the “HVPS ACIS Status Relay” in the UVC SCR Control Cabinet back to the ACIS system to indicate the off/on status of the HVPS, [4] provides a contact closure to the ACIS system that indicates the on/off status of the switched 120v ac power to the klystron (Kalmus) rf driver amplifier, [5] provides contact status outputs to the EPICS control system to indicate the interface box status, and [6] provides external reset capabilities of the ACIS/RF Interface Chassis from EPICS.  When RF1 is used to supply rf power to the 350MHz RF Test Stand, separate ACIS system for the 350MHz RF Test Stand utilizes this interface chassis to control RF1. ASD/RFG                                    ASD/SIG The Check out of RF 1 HV modulator. 2,3 *Defined as medium level not high because it is part of redundant RSS pair.    
RF 2 HV modulator and RF 2 Amplifier) Med.* 420 ACIS Interface Yes. RSS Boundary =  Consists of an interface chassis and wiring which performs the following functions: [1] routes ACIS permit contact closures to the RF2 UVC HVPS system utilizing the “external 3” contact interlock input which involves relay #3 on relay card #11 in the UVC control system, [2] switches 120v ac power to the RF2 klystron (Kalmus) rf driver amplifier, [3] routes a contact closure generated by the “HVPS ACIS Status Relay” in the UVC SCR Control Cabinet back to the ACIS system to indicate the off/on status of the HVPS, [4] provides a contact closure to the ACIS system that indicates the on/off status of the switched 120v ac power to the klystron (Kalmus) rf driver amplifier, [5] provides contact status outputs to the EPICS control system to indicate the interface box status, and [6] provides external reset capabilities of the ACIS/RF Interface Chassis from EPICS.  When RF2 is used to supply rf power to the 350MHz RF Test Stand, separate ACIS system for the 350MHz RF Test Stand utilizes this interface chassis to control RF2. ASD/RFG                                    ASD/SIG The Check out of RF 2 HV modulator. 2,3 *Defined as medium level not high because it is part of redundant RSS pair.    
RF 3 HV modulator and RF 3 Amplifier) Med.* 420 ACIS Interface Yes. RSS Boundary =  Consists of an interface chassis and wiring which performs the following functions: [1] routes ACIS permit contact closures to the RF3 UVC HVPS system utilizing the “external 3” contact interlock input which involves relay #3 on relay card #11 in the UVC control system, [2] switches 120v ac power to the RF3 klystron (Kalmus) rf driver amplifier, [3] routes a contact closure generated by the “HVPS ACIS Status Relay” in the UVC SCR Control Cabinet back to the ACIS system to indicate the off/on status of the HVPS, [4] provides a contact closure to the ACIS system that indicates the on/off status of the switched 120v ac power to the klystron (Kalmus) rf driver amplifier, [5] provides contact status outputs to the EPICS control system to indicate the interface box status, and [6] provides external reset capabilities of the ACIS/RF Interface Chassis from EPICS.  When RF3 is used to supply rf power to the 350MHz RF Test Stand, separate ACIS system for the 350MHz RF Test Stand utilizes this interface chassis to control RF3. ASD/RFG                                    ASD/SIG The Check out of RF 3 HV modulator. 2,3 *Defined as medium level not high because it is part of redundant RSS pair.    
RF 4 HV modulator and RF 4 Amplifier) Med.* 420 ACIS Interface Yes. RSS Boundary =  Consists of an interface chassis and wiring which performs the following functions: [1] routes ACIS permit contact closures to the RF4 UVC HVPS system utilizing the “external 3” contact interlock input which involves relay #3 on relay card #11 in the UVC control system, [2] switches 120v ac power to the RF4 klystron (Kalmus) rf driver amplifier, [3] routes a contact closure generated by the “HVPS ACIS Status Relay” in the UVC SCR Control Cabinet back to the ACIS system to indicate the off/on status of the HVPS, [4] provides a contact closure to the ACIS system that indicates the on/off status of the switched 120v ac power to the klystron (Kalmus) rf driver amplifier, [5] provides contact status outputs to the EPICS control system to indicate the interface box status, and [6] provides external reset capabilities of the ACIS/RF Interface Chassis from EPICS.  When RF4 is used to supply rf power to the 350MHz RF Test Stand, separate ACIS system for the 350MHz RF Test Stand utilizes this interface chassis to control RF4. ASD/RFG                                    ASD/SIG The Check out of RF 4 HV modulator. 2,3 *Defined as medium level not high because it is part of redundant RSS pair.    
Storage Ring Dipole Power Supply (S:BM) Med.* Bldg 420-A004 ACIS Interface Yes. RSS Boundary = Main Power Supply contactor and wiring and control relays associated with ACIS. ASD/PSG Dipole shutdown validation after work. 2,3 Connected to ACIS equipment.           *Defined as medium level not high because it is part of redundant RSS pair.    
Storage Ring 6 GEV Interlock system. High Bldg 420-A004 ACIS Interface Yes. RSS Boundary = Wiring to S.R. Dipole measuring current and voltage connected to ACIS. ASD/PSG 6 GEV top-up interlock validation after work. Connected to ACIS equipment.  
ACIS - Storage Ring Current Monitors High Sector 33:  36 current monitors ACIS Interface Yes. RSS Boundary = SR current monitors and equipment in RSS device path. ASD/Diagnostics 2,3 Two Storage Ring beam current monitors interface to the RF Area ACIS. 1  
ACIS - Storage Ring Dipole Power Supply Interface High   ACIS Interface Yes. RSS Boundary = SR Dipole PS interface and equipment in RSS device path. ASD/PSG 2,3 PS current and voltage > 6 Gev. 1  
Storage Ring Gate Interfaces High   ACIS Interface Yes. RSS Boundary = Each of the Storage Ring gates contains monitoring switches. ASD/MEG   ASD/SIG 2,3    
Rachet and Super Door Interfaces High   ACIS Interface Yes. RSS Boundary = Each ratchet door contains monitoring switches ASD/MEG   ASD/SIG 2,3    
Global On/Off Line Key switch (asserted ON when "On Line") High ASIE ACIS Interface Yes. RSS Boundary = ACIS ASD/SIG 3    
Sector 39 View screen High F Tunnel ACIS Interface Yes. RSS Boundary = Work in the SR tunnel on any S39 Flag component or cable ASD/Diagnostics 2,3 The closed position of the Sector 39 view screen is monitored by the ACIS  
ACIS - Radiation Monitor Interfaces High APS Facility ACIS Interface Yes. RSS Boundary = Radiation monitor and equipment in RSS device path up to ACIS connector.  AOD/UES      ASD/SIG 2,3 All five ACISs interface to numerous radiation monitors in the APS facility. 1  
ACIS - Building 420 Wave Guide Shutters High 420 ACIS Interface Yes. RSS Boundary = Wave Guide shutters and equipment in RSS device path. ASD/RFG 2,3 Two shutters are installed in the rf wave-guide that connects to the RF Test Stand. 1  
ACIS - Maze Door Interfaces High APS Facility ACIS Interface Type Yes. RSS Boundary = Doors - Mechs or facility, switches/lock ASD/SIG 2,3 Each maze door contains monitoring switches & lock  
ACIS - Chain A and B, PLC software and hardware and chain C hardware High * APS Facility ACIS Interface Yes. RSS Boundary = ACIS ASD/SIG 2,3 * Functional changes to the PLC software are considered High consequences.  However, remedial changes to the PLC software may be considered meduim.  
ACIS - Safety related devices Medium APS Facility ACIS Interface Yes. RSS Boundary = ACIS access keys, Door Locks, Search and Secure stations, and tamper monitoring ASD/SIG 2,3 Access keys, Door Locks, Search & Secure stations, and tamper monitoring   
Shielding Components in APS Accelerator (LINAC, BOOSTER, SR) High   ACIS Interface No.  RSS Boundary = Critical Components (red tags) and Components Under Configuration Control (yellow tags) that are not interfaced to either the ACIS or PSS. AOD/UES           
ACIS - Front End Equipment Protection System Low Facility ACIS Interface Yes. RSS Boundary = Closed switches ASD/SIG      
ACIS - Controlled Access CCTV System Medium Facility ACIS Interface Yes.  RSS Boundary = ACIS controlled access CCTV and equipment in RSS path. ASD/Controls  ASD/SIG 2,3 A CCTV/intercom system is used by MCR Operations to allow personnel access to the five machines at the maze doors while the ACIS is in Controlled Access Mode  
ACIS to PSS: shutter permit Medium   ACIS Interface Yes. RSS Boundary = ACIS to PSS ICD ASD/SIG 2,3 Shutter Permit (asserted ON when shutters may be opened)  
RF:  waveguide leakage monitors Medium   ACIS Interface Yes. RSS Boundary = Waveguide leakage monitors and equipment in RSS path. ASD/RFG   waveguide leakage monitoring  
RF1,2,3,4,5 Klystron garages personnel access control interlocks High 420 ACIS Interface No.  PSS Boundary = RF1,2,3,4,5 Klystron garage interlocks consists of Protection from klystron X-rays; consists of door switches and a Kirk-keyed lock/keyswitch. These contacts serve as two separate and isolated inputs to the RF1,2,3,4,5 Personnel Safety System Interface chassis, which shuts down the RF1,2,3,4,5 HVPS and klystron rf drive if the garage is opened.  ASD/RFG      
RF3/5 Isolation Waveguide Shutters High   ACIS Interface Yes. RSS Boundary = Two full-height WR2300 waveguide shutters that provide rf isolation in the waveguide run between waveguide switch #2 & waveguide switch #3.  This configuration provides rf isolation between RF3 & RF5, which is equivalent to isolation between the Booster & SR rf distribution systems. The open/closed position of the waveguide shutters is monitored by the SR & Booster ACIS system, utilizing dedicated position indication switches installed inside each waveguide shutter.  These position indication switches provide contact closures to the ACIS system through dedicated connectors & cabling from each shutter. The SR or Booster ACIS system monitors the psoition of both waveguide shutters and uses the shutter position to provide ACIS control of RF3 from the SR ACIS system or the Booster ACIS system, depending on which accelerator system RF3 is providing rf power to. Both of these waveguide shutters are equipped w/Kirk-interlock systems that allow the shutters to be locked in the closed position for LOTO purposes. The position of both waveguide shutters can be changed manually or by remote control from the Building 420 Waveguide Switching System. ASD/RFG      
Waveguide Air Pressure Interlocks Low   ACIS Interface Yes.  RSS Boundary = Protection from rf radiation from opening in the rf waveguide system by detecting a drop in slight positive air pressure maintained inside the waveguide system by the rf cavity coupler air blowers.  The system consists of 9 separate calibrated Photohelic air pressure guages installed at various positions in the waveguide system throughout Building 420. The alarm outputs of all Photohelic pressure guages (except for the Photohelic pressure gauge located at the 350MHz RF Test Stand, which is presently disabled) terminate at an interface chassis that routes shutdown commands to the RF Personnel Safety Interface Chassis all Storage Ring and Booster RF stations (RF1-TF5) in the event any single or comination of the Photohelic pressure guages rgisters an alarm. The RF Personnel Safety Interlock System at each rf station in turn disables the HVPS and klystron rf drive. ASD/RFG      
350MHz RF Test Stand RF Radiation Monitor Medium   ACIS Interface Yes. RSS Boundary = This rf radiation monitor provides an alarm contact closure to the 350MHz RF Test Stand ACIS system in the event the rf radiation level behind the test stand operator console exceeds approximately 0.10mW/sq-cm at 351.93MHz. ASD/RFG      
350 MHz RF Test Stand Bunker Isolation Waveguide Medium   ACIS Interface Yes.  RSS Boundary = Two full-height WR2300 waveguide shutters that provide rf isolation in the waveguide system for downstream personnel protection when the test cavity or connecting waveguide is disassembled for analysis, repair, or modification. The open/closed position of the waveguide shutters is monitored by the 350MHz RF Test Stand ACIS system utilizing dedicated position indication switches installed inside each waveguide shutter.  These position indication switches provide contact closures to the ACIS system through dedicated connectors and cabling from each shutter.  The 350MHz RF Test Stand ACIS system monitors the position of both waveguide shutters and uses the shutter position to either permit or inhibit the operation of RF1.  Both of these waveguide shutters are equipped with Kirk-interlock systems that allow the shutters to be locked in the closed position for LOTO purposes. The position of both of these waveguide shutters can be changed manually or by remote control from the 350MHz RF Test Stand PLC Control System.  ASD/RFG      
350MHz RF Test Stand 1MW RF Test Load Isolation Waveguide Shutters Medium   ACIS Interface Yes.  RSS Boundary = Two full-height WR2300 waveguide shutters that provide rf isolation in the waveguide system for downstream personnel protection in the connecting waveguide run between switch #4, the device test circulator, and the 1MW rf test load is disassembled for analysis, repair, or modification.  Both of these waveguide shutters are equipped with Kirk-interlock systems that allow the shutters to be locked in the closed position for LOTO purposes.  The position of both of these waveguide shutters is changed manually, or electrically by the use of local control boxes that are temporarily connected to the shutters.  ASD/RFG      
LEUTL:              
BBBM1 Power Supply High   ACIS Interface Yes. RSS Boundary = Contactor and other equipment in RSS path. ASD/PSG 2,3 1  
BBBM2 Power Supply High   ACIS Interface Yes. RSS Boundary = Contactor and other equipment in RSS path. ASD/PSG 2,3 1  
LEUTL:  End station access control Medium   ACIS Interface Yes. RSS Boundary = Personnel access control interlock system ASD/SIG      
Display computers and EPICS for ACIS Low    ACIS Interface Yes.  RSS Boundary = Display computers and EPICS interface ASD/SIG      
BEAMLINES              
Front Ends              
Photon Shutters 1 & 2 (PS1, PS2)   High 1BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2      (SS1, SS2)   High 1BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 1BM PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2          (PS1, PS2)   High 1ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2              (SS1, SS2)  High 1ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 1ID PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2       (PS1, PS2)   High 2BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2              (SS1, SS2)  High 2BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 2BM PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2      (PS1, PS2)  High 2ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                        (SS1, SS2)  High 2ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 2ID PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2             (PS1, PS2 ) High 3ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                      (SS1, SS2)   High 3ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 3ID PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2              (PS1, PS2)  High 4ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                   (SS1, SS2)  High 4ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 5BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                   (SS1, SS2)  High 5BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 5BM PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2                 (PS1, PS2)  High 5ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                     (SS1, SS2)   High 5ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 5ID PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 6BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                  (SS1, SS2)   High 6BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 6BM No PSS interface. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2                 (PS1, PS2)  High 6ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                  (SS1, SS2)  High 6ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 6ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 7BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)   High 7ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                 (SS1, SS2)  High 7ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 7ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2                (PS1, PS2)  High 8BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2                 (SS1, SS2)  High 8BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 8BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2           (PS1, PS2)  High 8ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2            (SS1, SS2)   High 8ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 8ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2         (PS1, PS2) High 9BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2         (SS1, SS2)   High 9BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 9BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 9ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 9ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 9ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 10BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 10BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 10BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 10ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 10ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 10ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 11BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 11BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 11BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 11ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 11ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2 High 11ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG      
Photon Shutter 1 & 2               (PS1, PS2)  High 12BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 12BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 12BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 12ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 12ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 12ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 13BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 13BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 13BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 13ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 13ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 13ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 14BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 14BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 14BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 14ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 14ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 14ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 15ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 15ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 15ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 16BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 16BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 16BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 16ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 16ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 & 4 High 16ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG      
Photon Shutter 1 & 2               (PS1, PS2)  High 17BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 17BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 17BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 17ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 17ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 17ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 18ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 18ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 18ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 19BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 19BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 19BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 19ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 19ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 19ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 20BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 20BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 20BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 20ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 20ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 20ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 22BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 22BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 22ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 22ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 & 4 High 22ID PSS Interface No. RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG      
Photon Shutter 1 & 2               (PS1, PS2)  High 23BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 23BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 23BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 23ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 23ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 High 24BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 24ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 24ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 26ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 26ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 30ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 30ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 31ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 31ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 & 4 High 31ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG      
Photon Shutter 1 & 2               (PS1, PS2)  High 32ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 32ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3 & 4 High 32ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG      
Photon Shutter 1 & 2               (PS1, PS2)  High 33BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 33BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3  High 33BM No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 33ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 33ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3  High 33ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 34ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 34ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Fixed Mask 1,2,3  High 34ID No PSS interface.  RSS Boundary = cooling, alignment ASD/VTG  ASD/MEG  XFD/XFE*   Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 35BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 35BM PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Photon Shutter 1 & 2               (PS1, PS2)  High 35ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
Safety Shutter 1 & 2               (SS1, SS2)   High 35ID PSS Interface Type - 1 & 2.  RSS Boundary = position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring and alignment. ASD/VTG  ASD/MEG ASD/SIG  XFD/XFE* 2,3 Open and Closed switches. 5                                           * New Front Ends being commissioned.  
 Shielding Components High   PSS Interface No.  RSS Boundary = The general type of beamline shielding components include: Lead bricks, ratchet wall collimators. ASD/VTG   XFD/XFE*   * New Front Ends being commissioned.  
Experimental Floor              
Collimator                          High 1BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Upstream end of 1-BM-A APS/AOD      
P6 Integral Shutter         High 1BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring Type-3 Downstream end of beamline of 1-BM-A APS/AOD   Open and Closed switches  
Lead Bricks                       High 1BM PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags. Type-3 Lead bricks on both sides of bellows at downstream wall of 1-BM-A APS/AOD      
P7 Integral Shutter        High 1BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring Type-3  P7-90 Downstream end of beamline APS/AOD   Open and Closed switches  
P8 Mono Shutter                     High 1BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring P8-30 Inside of minihutch 1-BM-B-MH-1 APS/AOD      
Collimator                          High 1ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-20, Upstream end of beamline in 1-ID-A with 2 lead stacks APS/AOD      
P4 Integral Shutter                      High 1ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring Type-4  Downstream end of beamline in 1-ID-A APS/AOD      
P5 Integral Shutter                      High 1ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring Type-4  Downstream end of 1-ID-B APS/AOD      
Collimator                          High 2BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K4-20 collimator upstream beamline in 2-BM-A APS/AOD      
P6 Integral Shutter           High 2BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring  Type-3  Downstream beamline in 2-BM-A APS/AOD      
Beam Stop                         High 2BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Downstream wall of 2-BM-B (water cooled plate & lead bricks covered with Plexiglas) APS/AOD      
Collimator                            High 2ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-20 collimator, Zero deg. (white beam) in 2-ID-A APS/AOD      
Mask                                    High 2ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask.. Type-4  M9-30 mask, Zero deg. (white beam) in 2-ID-A APS/AOD      
P9 Integral Shutter                    High 2ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring Type-4  P9-20/30/40 Integral Shutters (3), -0.3 deg (D/E line), 2.2 deg (C line), 4.7 deg (B line) (pink beam) in 2-ID-A hutch APS/AOD      
Collimator                             High 2ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-30 collimator, -0.3 deg. D/E beamline pink beam in 2-ID-A APS/AOD      
P9 Integral Shutter                                High 2ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P9-50 Integral shutter (pink beam), -.03 (pink/mono beam) in 2-ID-E APS/AOD      
Beam Stop                                        High 2ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  -0.3 deg pink beam, water cooled copper block in front of lead bricks @ downstream wall of 2-ID-D APS/AOD      
Collimator                            High 3ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Upstream beamline of 3-ID-A APS/AOD      
P5 Integral Shutter                                    High 3ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiringType-4  Downstream beamline of 3-ID-A APS/AOD      
P8 Mono Shutter                     High 3ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P-8 mono photon shutter - inside minihutch 3-ID-B-MH-2. APS/AOD      
P8 Mono Shutter                     High 3ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P-8 mono photon shutter - inside minihutch 3-ID-C-MH-1. APS/AOD      
Collimator                             High 4ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-20 Bremsstrahlung collimator in 4-ID-A APS/AOD      
Mask                                     High 4ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-4  White beam splitter mask (M7-40) in 4-ID-A APS/AOD      
Collimator                           High 4ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-40 (second) Bremsstrahlung collimator in 4-ID-A APS/AOD      
Beam Stop                           High 4ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  White beam stop in 4-ID-A APS/AOD      
P4 Integral Shutter                                        High 4ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-30 shutter assembly and bremsstrahlung stop in 4-ID-A APS/AOD      
Collimator                           High 4ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-30 Bremsstrahlung collimator APS/AOD      
P4 Integral Shutter                          High 4ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-40 shutter assembly of 4-ID-B APS/AOD      
Beam Stop                            High 4ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Pink beam stop inserted inside beam transport - inside lead box enclosure APS/AOD      
Beam Stop                            High 4ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  K5-50 beam stop at downstream end of station in 4-ID-D APS/AOD      
S2 Integral Shutter                         High 5BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  S2 style Integral Shutter, downstream beamline for both 5-BM-C and 5-BM-D APS/AOD      
Lead Bricks                                       High 5BM PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags. Type-3  Covering penetration for the BM-C/D lines. APS/AOD      
Collimator                              High 5BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Upstream end of Beam Transport (Inside Shielded Beam Transport) APS/AOD      
Collimator                         High 5BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Downstream end of Beam Transport (Inside Shielded Beam Transport) APS/AOD      
Beam Stop                         High 5BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Aluminum Plate located at inside backwall (end of 5-BM-C beamline) APS/AOD      
Beam Stop                        High 5BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Bremsstrahlung Stop located downstream end of station; end of 5-BM-C transport line APS/AOD      
Beam Stop                       High 5BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Bremsstrahlung Stop located downstream end of station; end of 5-BM-D transport line APS/AOD      
Beam Stop                       High 5BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Aluminum Plate located at inside backwall (end of 5-BM-D beamline) APS/AOD      
P8 Mono Shutter                     High 5BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring 5-BM-B beamline shutter, downstream wall APS/AOD      
Collimator                      High 5ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Upstream beamline APS/AOD      
Beam Stop                        High 5ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4   DND white beam stop at downstream of monochromator APS/AOD      
P5 Integral Shutter                        High 5ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5 Integral shutter, downstream beamline APS/AOD      
Bremsstrahlung Stop                   High 5ID PSS Interface No.  RSS Boundary = Shielding for bremstrallung. Type-4  Downstream of P5 shutter on same component stand APS/AOD      
Bremsstrahlung Stop                                       High 6BM PSS Interface No.  RSS Boundary = Shielding for bremstrallung.  Type-3  Beam stop at downstream end of 6-BM-B APS/AOD      
Collimator                          High 6ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-20 Collimator upstream end of 6-ID-A APS/AOD      
P5 Integral Shutter                     High 6ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5-20 Integral Shutter located downstream end of 6-ID-A APS/AOD      
P8 Mono Shutter                     High 6ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Downstream wall for 6-ID-D APS/AOD      
Collimator                             High 7ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator Assembly and F2-30 Filter APS/AOD      
P4 Integral Shutter             High 7ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-20 Integral Shutter located at the downstream end of 7-ID-A APS/AOD      
P5 Integral Shutter         High 7ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5 Integral Shutter - inside minihutch 7-ID-B-MH-1 APS/AOD      
 Collimator                         High 8BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K - Upstream of Monochromater APS/AOD      
P7 Integral Shutter            High 8BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  P7-20 Integral Shutter, Downstream end of 8-BM-A APS/AOD      
Collimator                          High 8ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment.Type-4  K3-20 Collimator upstream end of beamline in 8-ID-A APS/AOD      
Mask                                  High 8ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask.Type-4  M9-30 Mask downstream end of 8-ID-A immediately upstream of P9-30 Integral Shutter APS/AOD      
P9 Integral Shutter               High 8ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P9-30 Integral Shutter at the downstream end of 8-ID-A APS/AOD      
Collimator                             High 8ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-30 Collimator, Bremstrahlung stop at the downstream end of 8-ID-A APS/AOD      
Beam Stop                       High 8ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper block at the downstream end of 8-ID-I APS/AOD      
Mono Shutter High 8ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Wide angle monochromatic shutter for the 8-ID-E branch of beamline APS/AOD      
Bremsstrahlung Shielding       High 9BM PSS Interface No.  RSS Boundary = Shielding for bremstrallung. Type-3  Lead bricks for bremstrallung stop downstream of White Beam Slits APS/AOD      
Bremsstrahlung Shielding         High 9BM PSS Interface No.  RSS Boundary = Shielding for bremstrallung.  Type-3  Lead/tungsten bricks for bremstrallung stop - White Beam Absorber APS/AOD      
P8 Mono Shutter                     High 9BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P-8 monoshutter downstream end of 9-BM-A APS/AOD      
Beam Stop                         High 9ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Lead bricks for Bremsstrahlung stop; upstream end of 9-ID-A APS/AOD      
Beam Stop                        High 9ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled Tungsten fixed mask; downstream end of 9-ID-A APS/AOD      
Beam Stop                         High 9ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Lead bricks for bremstrallung stop; downstream end of 9-ID-A APS/AOD      
Front End Components          High 10BM Type-3  Plate, collimator with vac. gauges, vacuum valve (FEV), and bellows/pump section, water cooled Be. windows; upstream beamline APS/AOD      
Horizontal Fixed Mask (90mm x 6mm)                   High 10BM PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-3  Water Cooled Cu block with 90mm X 6mm aperture. Fixed in the horizontal position but movable vertically. Horizontal motor under Configuration Control. APS/AOD      
Collimator                            High 10BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Bremsstrahlung Collimator: Pb stack centered at beam height approximately 8" H x 16" W x 12" D. Aperture 124mm x 20.5mm. APS/AOD      
Beam Stop                         High 10BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Photon Stop: Aluminum Plate with water-cooled Cu block at downstream wall in front of Bremsstrahlung Stop in 10-BM-A APS/AOD      
Beam Stop                               High 10BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Bremsstrahlung Stop - Lead brick stack at downstream end of 10-BM-A APS/AOD      
Collimator                           High 10ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Upstream end of beamline in 10-ID-A APS/AOD      
P5 Integral Shutter                    High 10ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5 Inverted, Integral shutter, midstream beamline (consists of white beam stop,safety stop, & mono shutters) APS/AOD      
P8 Mono Shutter                     High 11BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Downstream end of 11BM-A APS/AOD      
Mask                                   High 11ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-4  M_-_ mask (white beam), in 11-ID-A APS/AOD      
Beam Stop                        High 11ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Collimator; upstream beamline (tungsten beam stop) APS/AOD      
Beam Stop                         High 11ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Collimator; upstream beamline (first lead beam stop) APS/AOD      
Beam Stop                          High 11ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  downstream beamline (white beam stop) APS/AOD      
Beam Stop                         High 11ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Collimator; downstream beamline (tungsten beam stop) APS/AOD      
Beam Stop                           High 11ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Collimator; downstream beamline (second lead beam stop) APS/AOD      
P8 Mono Shutter                     High 11ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P8 Integral Shutter & Slit Assembly, downstream beamline APS/AOD      
P8 Mono Shutter                     High 11ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter & Slit Assembly, downstream beamline APS/AOD      
P8 Mono Shutter                     High 11ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter and slit assembly for the B branchline APS/AOD      
P8 Mono Shutter                     High 11ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter and slit assembly for the C branchline APS/AOD      
Collimator                          High 12BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K2 collimator, upstream beamline of 12-BM-A APS/AOD      
P6 Integral Shutter         High 12BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  P6 Integral Shutter downstream end of 12-BM-A locked in mono mode APS/AOD      
Collimator                             High 12ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator upstream end of 12-ID-A APS/AOD      
P4 Integral Shutter               High 12ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4 Integral Shutter located downstream end of 12-ID-A locked in mono mode APS/AOD      
Collimator                                High 13BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ Collimator#1 downstream beamline in 13-BM-A (inside vacuum tank) APS/AOD      
Collimator                           High 13BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ Collimator#2 downstream beamline outside 13-BM-A APS/AOD      
Shutter: SH1-C                      High 13BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  shutter for BM-C branchline APS/AOD      
Shutter: SH2-D                    High 13BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  shutter downstream beamline 13-BMB APS/AOD      
Collimator                           High 13BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ Collimator#3 downstream beamline in 13-BM-B APS/AOD      
Beam Stop                          High 13BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Steel encased lead located at downstream end of 13-BM-C APS/AOD      
Beam Stop                       High 13BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Steel plate and lead bricks located at downstream end of 13-BM-D APS/AOD      
Mask                                     High 13ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-4  M_-_ Mask: Pinhole Assembly 400W and 100W water-cooled mask inside tank located at downstream end of 13-ID-A APS/AOD      
Collimator                            High 13ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator#4 downstream beamline in 13-ID-A (inside vacuum tank) APS/AOD      
Collimator                            High 13ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator#5 downstream beamline inside 13-ID-A APS/AOD      
Beam Stop                           High 13ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Movable White Beam Stop downstream wall of 13-ID-C (water cooled Cu block (13.5) APS/AOD      
Lead Bricks                          High 13ID PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags. Type-4  Lead bricks inside of Movable White Beam Stop downstream wall of 13-ID-C APS/AOD      
Beam Stop                         High 13ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Lead bricks and water cooled copper block inside 13-ID-D APS/AOD      
Collimator                          High 14BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ Collimator #1 inside and between conditioning tank and monochromator tank, upstream end of beamline in 14-BM-A APS/AOD      
Beam Stop                         High 14BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  K_-_ Collimator #2 inside and between conditioning tank and monochromator tank, upstream end of beamline in 14-BM-A APS/AOD      
Beam Stop                         High 14BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Bremsstrahlung and White Beam Stop inside Diagnostics tank downstream end of 14-BM-A APS/AOD      
P9 Integral Shutter           High 14BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring.  Type-3  Pink Beam Shutter downstream end of 14-BM-B for the C branchline APS/AOD      
P9 Integral Shutter           High 14BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  Pink Beam Shutter downstream end of 14-BM-B for the D branchline APS/AOD      
Beam Stop                           High 14BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Pink Beam Stop inside 14-BM-D APS/AOD      
Collimator                             High 14ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator #1, downstream of slit assembly, upstream of monochromator tank in 14ID-A APS/AOD      
Beam Stop                          High 14ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung and White Beam Stop inside Diagnostics tank downstream end of 14-ID-A APS/AOD      
Pink Shutter                      High 14ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  Pink shutter, downstream beamline APS/AOD      
Beamline Interlock            High 14ID Type-4  Back to back copper canister at the downstream wall of 14-ID-B APS/AOD      
Collimator                            High 15ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator upstream end of beamline in 15-ID-A APS/AOD      
P4 Integral Shutter                High 15ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-15 Integral Shutter located at the downstream end of 15-ID-A. Locked in mono-mode APS/AOD      
Lead Sheet                           High 15ID PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags. Type-4  Upstream wall 15-ID-A-MH-1 APS/AOD      
Beam Stop                        High 15ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper stop on steel encased lead located at the downstream end of 15-ID-B APS/AOD      
Beam Stop                          High 15ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper stop on steel encased lead located at the downstream end of 15-ID-B APS/AOD      
Beam Stop                        High 15ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper stop located at the downstream end of 15-ID-D APS/AOD      
Photon Shutter/Mask         High 16BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  Photon shutter and water-cooled beam splitter mask are located upstream 16-BM-A APS/AOD      
Collimator                  High 16BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Tungsten Bremstrahlung collimator housed in vessel located downstream 16-BM-A APS/AOD      
S3 Integral Shutter               High 16BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  BM-B White Beam Shutter downstream end of 16-BM-A APS/AOD      
S3 Integral Shutter                High 16BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  BM-D White Beam Shutter downstream end of 16-BM-A APS/AOD      
Collimator                  High 16BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Lead brick Bremstrahlung Collimator downstream beamline 16-BM-A APS/AOD      
Beam Stop                         High 16BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Aluminum plate and stack of lead bricks located downstream end of 16-BM-B APS/AOD      
Collimator                         High 16ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-20 Collimator upstream end of 16-ID-A located on FE table after the ion pump APS/AOD      
Mask                                   High 16ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-4  M_-_ Mask: Pinhole Assembly 400W and 100W water-cooled mask located downstream of monochromator tank in 16-ID-A: (3) Al blocks restricting mask movement APS/AOD      
Collimator                          High 16ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Lead stack located downstream of monochrometer tank in 16-ID-A APS/AOD      
Beam Stop                          High 16ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  100W thermal stop located downstream of 16-ID-A-K-02 Collimator in 16-ID-A APS/AOD      
S3 Integral Shutter              High 16ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  S3-30 integral shutter APS/AOD      
Collimator                          High 16ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator inside tank located on upstream table in 16ID-C APS/AOD      
Photon Stop                         High 16ID Type-4  Photon Stop located downstream end of 16ID-C, directly upstream of S3-30 shutter APS/AOD      
S3 Integral Shutter                High 16ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4   S3-30 shutter located downstream end of 16ID-C APS/AOD      
Beam Stop                         High 16ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper white beam stop. APS/AOD      
Beam Stop                          High 16ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bolt restricting movement of the beamstop under configuration control, on the back wall of 16-IDD. APS/AOD      
Lead Bricks                        High 16ID PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags.  Type-4  Movable lead bricks on the back wall of 16-ID-D APS/AOD      
P8 Mono Shutter                     High 16ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8-60 Integral Shutter located at downstream end of 16-ID-A APS/AOD      
Collimator                        High 17BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K1/mod Bremsstrahlung Collimator (Bremsstrahlung Shield #1) APS/AOD      
White/Pink Beam Absorber      High 17BM Type-3  White/Pink Beam Absorber (SCRRI Design) located downstream of Mono APS/AOD      
P6 Mod Integral Shutter      High 17BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  P6 Modified Integral Shutter located at the downstream end of 17-BM-A (locked in mono mode) APS/AOD      
Bremstrahlung Shield #3         High 17BM PSS Interface No.  RSS Boundary = Shielding for bremstrallung. Type-3  Bremstrahlung Shield #3 downstream of P6 Mod Shutter APS/AOD      
Collimator                          High 17ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K1 Bremsstrahlung Collimator APS/AOD      
P5-20 Mod Integral Shutter   High 17ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5-20 Modified Integral Shutter APS/AOD      
Collimator                            High 18ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #1 located at upstream end of 18-ID-A APS/AOD      
Collimator                           High 18ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #2 located at downstream end of 18-ID-A APS/AOD      
Collimator                          High 18ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #3 located upstream of first monochromater in 18-ID-C APS/AOD      
Beam Stop                         High 18ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  White Beam stop located inside second monochromater of 18-ID-C APS/AOD      
Collimator                             High 18ID Type-4  Collimator #4 located downstream of second monochromater in 18-ID-C APS/AOD      
P8 Mono Shutter                     High 18ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter located at the downstream end of 18-ID-C APS/AOD      
Collimator                           High 19BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Collimator #1 upstream beamline in 19-BM-A on support #1 APS/AOD      
Collimator                           High 19BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Collimator #2 downstream beamline in 19-BM-A on support #2 APS/AOD      
Collimator                          High 19BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Collimator #3 located upstream of monochromater in 19-BM-C APS/AOD      
Monochromater                  High 19BM Type-3  Monochromater tank (only) APS/AOD      
Collimator                         High 19BM Type-3  Collimator #4 located downstream monochromater in 19-BM-C APS/AOD      
P8 Mono Shutter                     High 19BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter downstream of 19-BM-C-K-02 in 19-BM-C APS/AOD      
Collimator                        High 19ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #1 upstream beamline in 19-ID-A on support #1 APS/AOD      
Collimator                          High 19ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #2 downstream beamline in 19-ID-A on support #2 APS/AOD      
Collimator                          High 19ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #3 located upstream of first monochromater in 19-ID-C APS/AOD      
Beam Stop                          High 19ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  White Beam Stop located inside of second monochromater tank in 19-ID-C APS/AOD      
Collimator                         High 19ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator #4 located downstream of second monochromater in 19-ID-C APS/AOD      
P8 Mono Shutter                     High 19ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter downstream of 19-ID-C-K-02 in 19-ID-C APS/AOD      
Mask                                High 20BM PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask. Type-3  White Beam Mask on FE table APS/AOD      
K2-21 Collimator               High 20BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K2-21 Collimator upstream beamline in 20-BM-A on support stand APS/AOD      
P7-23 WB Stop                   High 20BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  P7-23 WB Stop on component stand with mono shutter and Bremsstrahlung stop APS/AOD      
Beam Stop                    High 20BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Bremsstrahlung Stop on compent stand with mono shutter and WB Stop APS/AOD      
Mono Shutter High 20BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Mono shutter on compent stand with WB Stop and Bremsstrahlung stop APS/AOD      
Collimator                           High 20ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-21 Collimator upstream beamline in 20-ID-A on support stand APS/AOD      
P5 Integral Shutter                     High 20ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5 Integral Shutter consisting of white beam stop, safety stop and shutters APS/AOD      
Collimator                          High 22BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Upstream beamline (including lead bricks) APS/AOD      
Collimator                        High 22BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Downstream beamline (including lead bricks) APS/AOD      
Collimator                         High 22BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ collimator upstream of monochromater (including lead bricks) APS/AOD      
Monochromater                  High 22BM Type-3  Downstream wall of Monochromater tank (only) APS/AOD      
Collimator                         High 22BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  K_-_ collimator located downstream of monochromater (including lead bricks) APS/AOD      
P8 Mono Shutter                     High 22BM PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter - Dual shutter system APS/AOD      
Collimator                          High 22ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-20 Bremsstrahlung collimator in 22-ID-A APS/AOD      
Collimator                          High 22ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator downstream beamline in 22-ID-A on support stand APS/AOD      
Collimator                            High 22ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator located upstream of monochromator in 22-ID-C (including lead bricks) APS/AOD      
Beam Stop                          High 22ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  White Beam Stop located inside of monochromator tank in 22-ID-C APS/AOD      
Collimator                            High 22ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator located downstream of monochromator in 22-ID-C (including lead bricks) APS/AOD      
P8 Mono Shutter                     High 22ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. P8 Integral Shutter - Dual shutter system APS/AOD      
Front End Components              High 23ID Type-4  Ratchet wall plate, collimator with vac. gauges, vacuum valve (FEV), bellows section, ion pump section, water cooled mask, water cooled Be. windows; APS/AOD      
Integral Beam Stop (IBST)                High 23ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Synchrotron and bremsstrahlung stop for outboard beam, water-cooled Cu block and inboard bremsstrahlung collimator APS/AOD      
Integral Beam Shutter (IBSH)   High 23ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  Being used as a collimator or shutter for the inboard beam APS/AOD      
Collimator                           High 23ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  White Beam Collimator (WBCO) for Inboard beam APS/AOD      
Integral Beam Stop (IBST)                High 23ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  (IBST-in): white beam stop for the inboard beam, bremsstrahlung stop on same table- mono beam passes though; downstream of monochromator APS/AOD      
Mono Shutter High 23ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Monochromatic Beam Shutter (MBSH) for Outboard beam APS/AOD      
Mono Shutter High 23ID PSS Type 3 & 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. mono beam shutter located downstream end of 23-ID-C APS/AOD      
Front End Components         High 24ID Type-4  Ratchet wall plate, collimator with vac. guages, vacuum valve (FEV), bellows section, ion pump section, water coooled mask, water cooled Be. windows: APS/AOD      
Fixed Aperature Mask Assembly               High 24ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags.  Typical types are M9-30 mask.. Type-4  Inboard and outboard power limiting aperatures (design similiar to an APS L5-92 mask) APS/AOD      
Tungsten Collimator             High 24ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Located between the fixed aperature mask assembly and the bremsstrahlung collimator in 24ID-A APS/AOD      
Bremsstrahlung Collimator        High 24ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Located immediately downstream of the Fixed Aperature Mask Assembly APS/AOD      
Tungsten Collimator        High 24ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  located directly upstream of the bremsstrahlung collimator APS/AOD      
Bremsstrahlung Collimator           High 24ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  located directly downstream of the tungsten collimator in 24-ID-B APS/AOD      
Beam Stop                            High 24ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  stops inboard beam; located downstream of the bremsstrahlung collimator APS/AOD      
P4 Integral Shutter         High 24ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-50 Integrated white beam stop (collimator and shutter) located in downstream 24-ID-B APS/AOD      
Beam Stop                         High 24ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Stack of lead bricks flush to the upstream wall of 24ID-C APS/AOD      
Front End Components        High 26ID Type-4  Wall collimator plate, bremsstrahlung collimator, vacuum gauges, vacuum valve (FEV), bellows section, ion pump section, water-cooled mask, water-cooled Be windows in upstream beamline APS/AOD      
Beam Stop                         High 26ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Temporary Beam Stop located at the downstream end of 26ID-A APS/AOD      
Bremsstrahlung Stop           High 27ID PSS Interface No.  RSS Boundary = Shielding for bremstrallung.  Type-4  directly downstream of IBST-in, mono beam passes through APS/AOD      
Lead Bricks                         High 27ID PSS Interface No.  RSS Boundary = Lead bricks that have red configuration tags. Type-4  lead bricks covering the exit port on the back wall of 23-ID-C APS/AOD      
Beam Stop                           High 30ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  White beam stop APS/AOD      
P5 Integral Shutter          High 30ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5-80 Integral shutter with locks on shutter cylinders APS/AOD      
Collimator                        High 31ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K5-20 Collimator downstream of the commissioning window APS/AOD      
Collimator                        High 31ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator (Lead stack assembled on component stand) APS/AOD      
Mask                                  High 31ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-4  L5-92 water cooled mask APS/AOD      
Collimator                        High 31ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Tungsten APS/AOD      
Collimator                         High 31ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Collimator (Lead stack assembled on component stand) APS/AOD      
Beam Stop                           High 31ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled White Beam Stop upstream of P4 shutter in 31-ID-C APS/AOD      
P4 Integral Shutter           High 31ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-50 Modified Shutter (table apparatus also supports 31-ID-C-P-01 White Beam Stop (locked in Mono Mode)) APS/AOD      
Beam Stop                          High 31ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water Cooled White Beam Stop in 32-ID-A APS/AOD      
P4 Integral Shutter            High 31ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-50-S3-30 Integral Shutter (table apparatus also holds White Beam Stop) (locked in Mono Mode) APS/AOD      
Beam Stop                           32ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water Cooled White Beam Stop in 32-ID-A APS/AOD      
P4 Integral Shutter                32ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P4-50-S3-30 Integral Shutter (table apparatus also holds White Beam Stop) (locked in Mono Mode) APS/AOD      
Mask                               High 33BM PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-3  Beryllium Window at upstream end of 33-BM-A APS/AOD      
Collimator                            High 33BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Collimator: lead stack associated with the L3 slits at the upstream end of 33-BM-A APS/AOD      
Mask                                High 33BM PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-3  White Beam Mask just downstream of the monochromator in 33-BM-A APS/AOD      
Collimator                            High 33BM PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-3  Bremsstrahlung collimator (lead stack) associated with P7 shutter APS/AOD      
P7 Integral Shutter               High 33BM PSS Type 3.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-3  P7-30 Integral Shutter - Lead and Tungsten Bremsstrahlung stop at 30.175 m and 30.68 m APS/AOD      
Collimator                         High 33ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K1 Collimator downstream end of 33-ID-A APS/AOD      
Mask                                    High 33ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-4  M_ Mask (water cooled) located at upstream end of 33-ID-C APS/AOD      
Collimator                         High 33ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K_-_ Collimator (Bremsstrahlung) under vacuum upstream end of 33-ID-C APS/AOD      
Beam Stop                            High 33ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled beam stop located downstream of monochromator in 33-ID-C APS/AOD      
P5 Integral Shutter            High 33ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P5 Integral Shutter with Bremsstrahlung stop APS/AOD      
Mask                                High 34ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-4  M4-30/S1 Mask (water cooled) located at upstream end of 34-ID-A APS/AOD      
Collimator                          High 34ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-22 Vertical (tubular) Collimator on component stand APS/AOD      
Collimator                           High 34ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-22 Horizontal lead brick Collimator APS/AOD      
Mask                                 High 34ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-4  61 Mask (water cooled) Septum Mask located at upstream end of 34-ID-B APS/AOD      
Mask                                   High 34ID PSS Interface No.  RSS Boundary = Mask, cooling and alignment that have red configuration tags. Type-4  L5-83 Mask (water cooled) located at upstream end of 34-ID-B (inboard) APS/AOD      
Collimator                           High 34ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-22-5 Collimator at upstream end of 34-ID-B APS/AOD      
Collimator                           High 34ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  K3-22 Collimator at upstream end of 34-ID-B (lead bricks) APS/AOD      
P9 Integral Shutter            High 34ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P9-30 Integral Shutter at the downstream end of 34-ID-B APS/AOD      
Beam Stop                         High 34ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper beamstop APS/AOD      
P9 Integral Shutter                High 34ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  P9-30 Integral Shutter used as photon absorber APS/AOD      
S3 Integral Shutter                  High 34ID PSS Type 4.  RSS Boundary = Position switches, cylinders, pneumatics, DIW cooling up to the PSS wiring. Type-4  S3-30 Integral Shutter with Tungsten Beamstop APS/AOD      
Beam Stop                          High 34ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper beamstop APS/AOD      
Beam Stop                          High 34ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Stop outside downstream end of 34-ID-E APS/AOD      
Beam stop                        High 35BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Copper Block used as Beam Stop at downstream end of 35-BM-C APS/AOD      
Beam stop                     High 35BM PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-3  Lead Beam Stop contained in aluminum casing at downstream end of 35-BM-C APS/AOD      
Collimator                         High 35ID PSS Interface No.  RSS Boundary = collimator, cooling & alignment. Type-4  Bremsstrahlung Collimator located downstream of Front End Components in 35-ID-A APS/AOD      
Beam Stop                            High 35ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Water cooled copper block in 35-ID-A APS/AOD      
Beam Stop                           High 35ID PSS Interface in some cases.  RSS Boundary = Either Synchrotron or Bremsstrahlung Stops. Type-4  Bremsstrahlung Stop located in 35-ID-A APS/AOD      
Station Labyrinths High   PSS Interface No.  RSS Boundary = Engineered radiation shielding interface. APS/AOD      
BEAMLINES              
PSS - In General  High All Beamlines PSS Safety critical hardware and software ASD/SIG      
PSS - Safety Related Devices Medium   Search and Secure stations, warning alarms and beacons, door magnetic locks, PSS USER Key ASD/SIG      
PSS - Beam Line Shutters = Mode Locks Medium   Kirk locks when installed on mode shutters ASD/SIG      
PSS - BLEPS Interface Low   PSS Interface Type - 5.  RSS Boundary = Isolated relay contact ASD/SIG      
PSS - Remote Shutter Interface and Chassis Low   PSS Interface Type - 5.  RSS Boundary = Isolated relay contact ASD/SIG      
PSS - Pneumatic Door Interface Low   PSS Interface Type - 5.  RSS Boundary = Terminal strip in box ASD/SIG      
PSS - FEEPS Interface Low   PSS Interface Type - 5.  RSS Boundary =  Isolated relay contact ASD/SIG      
PSS - Generation-3 PSS Chain-C I/O Low   PSS Interface Type - 5.  RSS Boundary = Electrically isolated. ASD/SIG