If a magnet fails to pass the Go-Nogo gauge test, repeat the test. If it fails again then immediately page H.Friedsam 
(4-1864) and S.Sharma (4-6820). Their backups are M.Penicka (4-1863) and R.Bechtold (4-2906), respectively.
The completed test data sheet is to be hand delivered (not left in the mailbox) to H. Friedsam or his backup and            
R. Bechtold so it can be posted on the web as soon as possible.                                                                       
Vacuum Chamber Clearances
  Sector Girder 1 Girder 2 Girder 3 Girder 4 Girder 5
F 1 X X X X X
A 2 X X X X X
  3 X X X X X
  4 X X X X X
  5 X X X X X
  6 X X X X X
  7 X X X X X
  8 X X X X X
  9 X X X X X
B 10 X X X X X
  11 X X X X X
  12 X X X X X
  13 X X X X X
  14 X X X X X
  15 X X X X X
  16 X X X X X Sext.Gauge size:(Go) 4.979" (Nogo) 5.147" 
  17 X X X X X Girder-2 Girder-4
C 18 X X X X X AS2-AS3 BS3-BS2
  19 X X X X X The gage is to be inserted at the location marked by the red arrows
  20 X X X X X
  21 X X X X
X
  22 X X X X X
  23 X X X X X
D 24 X X X X X
  25 X X X X X
  26 X X X X X
  27 X X X X X
  28 X X X X X
  29 X X X X X
E 30 X X X X X
  31 X X X X X
  32 X X X X X
  33 X X X X X
  34 X X X X X
  35 X X X X X
F 36 X X X X X
  37 X X X X X
  38 X X X X X Quad.Gauge size:(Go) 9.624"(Nogo) 9.792"
  39 X X X X X Girder-1             Girder-3             Girder-5
  40 X X X X X AQ1-AQ3          AQ4-BQ4          BQ3-BQ1