Upcoming ESAFs that will need Electrical Equipment Inspectors :
| PEN | Title | PI | Institution | Start Date | Req. Made |
Requestor | Date/Time | Inspector |
Comment | OK |
|
93896 |
Nanoparticle Synthesis in droplet-generating microfluidic devices – Examining the influence of 3-D phase space (temperature-concentration-time) on nucleation and growth by high-energy x-ray scattering | Robert Rioux | The Pennsylvania State University | 4/20/2012 | Y | Nick Sturgis | 4/18/2012 @ 0800 | Kevin Beyer | We are bringing two syringe pumps that are not NRTL inspected. They are unmodified Harvard Apparatus PHD2000 syringe pumps. One has been inspected previously (Nov 2011) and has not been opened/modified since inspected (or ever). The other has not been inspected in the past and has not been opened/modified. |
|
|
94091 |
High-Pressure HEDM: shedding new light on phase transformations | Joel Bernier | Lawrence Livermore National Laboratory | 4/18/2012 | Y | Joel Bernier | 04/17/2012 @ 0900 | Dean Wyncott | *) Power supply for DAC heater (previously inspected) *) Gas manifold controller (previously inspected) Location: 1-ID-C |
Y |
|
93502 |
Exploration on Droplet Nucleation and Growth Processes Within Supercritical Ethylene Jets | Kuo-Cheng Lin | Taitech, Inc. | 4/18/2012 | Y | Kuo-Cheng Lin | 4/17/2012 @ 1400 | Clay White | Electrical box for instrumentation and control (APS Electrical bar code # E002767) Chiller (0.5 ton Air Cooled Portable Chiller, 115 Vac, Model number: CF.5A, Vender: TempTek, phone: 317-887-6352) Location: 12-ID-B |
Y |
|
92188 |
In-situ Investigation of Growth Procedures used to Obtain Supported, Monodisperse Nanoparticles. | Joshua Hammons | Vrije Universiteit Brussel | 4/18/2012 | Y | Joshua Hammons | 4/16/2012 @ 0800 | Jonathan Baldwin / Jay von Osinski | Harvard Syringe Pump Ivium potentiostat Location: 15-ID |
Y |
|
94002 |
Flow-Induced Crystallization of poly(1-butene) | Wesley Burghardt | Northwestern University | 4/16/2012 | Y | Wesley Burghardt | 4/16/2012 @ 1100 | Jonathan Baldwin | All electrical equipment has been previously subjected to electrical safety inspection (tag numbers listed below): The shear flow experiments use the following equipment: Linkam shear cell & controller: E001401 Recirculating water bath: E020043 The extensional flow device includes several components with 110V AC power: Test station/oven: E042703 Temperature controller (Omega): E042700 Limit controller (Omeaga): E042702 The last 3 items were recently used and inspected at Sector 12; the inspector on that occasion indicated he would assign an expiration date of May 1 for the oven/test station, and later for the Omega components. I'm not sure I understand fully, but perhaps these items will not require inspection this time. However, the Linkam shear cell and water bath were not part of this, and hence definitely need inspection.". Manuals or documentation is available. Location: 5-ID-D |
Y |
|
93462 |
In-situ, high resolution X-ray diffraction for modified high voltage cathode materials used in Li ion batteries. | Shailesh Upreti | Primet Precision Materials, Inc. | 4/4/2012 | Y | Shailesh Upreti | 4/4/2012 @ 0800 | Dean Wyncott | It is cell testing instrument with 10 volt output limit. Location: 01-BM-C |
Y |
|
93402 |
Characterization of melting, solidification, and thermomechanical cycling processes in lead-free solder joints | Thomas Bieler | Michigan State University | 3/24/2012 | Y | Thomas Bieler | 3/24/2012 @ 1200 | Bruno Fieramosca | temperature controller that will mounted properly in an instrument enclosure Location: 6-ID-D |
Y |
|
93123 |
Synchrotron Footprinting of Gp41-based Antigens | Jennifer Bohon | Case Western Reserve University | 3/29/2012 | Y | John Katsoudas | 3/21/2012 @ 1000 | Bruno Fieramosca | Harvard '33' Syringe Pump Turner Biosystems TBS-380 Handheld Fluorimeter Location: Sector 10 |
Y |
|
93081 |
Time-Resolved Diffraction of Thin Films during Electric Field Application: Determination of Origin of Nonlinearity | Jacob Jones | University of Florida | 3/21/2012 | Y | Jacob Jones | 3/20/2012 @ 0900 | Rick Spence | -HP4284A precision LCR meter -AVC instrumentation (PCB piezotronics) 790 Series Power amplifier [max output 200V 100mA]. It outputs 10x. -Keithley 2400 source meter (previously used at APS) -Agilent 33220A function generator (previously used at APS) Location: 11-ID-C |
Y |
|
93022 |
Pressure dependent thermal expansion in the tailored low and negative thermal expansion materials [ScF3]1-x[AlF3]x | Angus Wilkinson | Georgia Institute of Technology | 3/21/2012 | Y | Angus Wilkinson | 3/20/2012 @ 1000 | Kevin Beyer | Temperature controller and catridge heaters. This has previously been inspected at APS, but it has not been resident at APS Location: 11-ID-B |
Y |
|
91241 |
Charged Nanoparticles at the Electrified Liquid-Liquid Interface | Mrinal Bera | The University of Chicago | 3/19/2012 | Y | Mrinal Bera | 3/19/2012 @ 1400 | Clay White | 1. solatron 1287 : serial number inspection tag : E002758 2. solvent agitator(big one) : serial number inspection tag : E002756. 3. Spectrum analyzer(SR760):serial number inspection tag :E011122 4. Wide Bandwidth Amplifier:serial number inspection tag :E042697
Location: 434D Chem Lab |
Y |
|
93127 |
install ion-gun | Jonathan Tischler | Argonne National Laboratory | 3/15/2012 | Y | Jonathan Tischler | 3/14/2012 @ 1100 | Lynette Jirik | ion-gun power supply | Y |
|
92927 |
Inhibition of Insulin Aggregate Formation in Solution Investigated by SAXS | Kiersten Batzli | University of Michigan | 3/14/2012 | Y | Wesley Burghardt | 3/14/2012 @ 1000 | Clay White | Compumotor motion control indexer (E025772) Compumotor driver (E025773) (previously inspected, tag numbers) Location: 433E030 |
Y |
|
92959 |
Exchange interactions between a ferromagnetic layer and an antiferromagnetic BiFeO3 thin films with ferroelectric mono-domains | Chang-Beom Eom | University of Wisconsin-Madison | 3/14/2012 | Y | Sangwoo Ryu | 3/14/2012 @ 1000 | Mike McDowell | Ferroelectric Tester made by Radiant Technology Location: 4-ID-C |
Y |
|
92962 |
High energy diffraction of coin batteries. | William (Mike) Guise, Jr. | E.I. DuPont de Nemours & Company | 3/16/2012 | Y | Mike Guise | 3/8/2012 | Jay Von Osinski | EG&G Model 362 Scanning Potentiostat Location: 432A030 |
Y |
|
92438 |
Scanning transmission X-ray microscopy and coherent diffraction imaging using a mixed mode pixel array detector | Sol Gruner | Cornell University | 3/9/2012 | Y | Mark Tate | 3/7/2012 @ 1300 | Jonathan Baldwin | Cornell MMPAD x-ray detector Location: 2-ID-B |
Y |
|
91864 |
Mechanical characterization and morphology of polymer membranes for alkaline fuel cells | Matthew Liberatore | Colorado School of Mines | 3/9/2012 | Y | Benjamin Caire | 3/6/2012 @ 1500 | Lynn Ribaud and Rick Spence | Several electrical components associated with the the extensional flow device and humidity oven will require inspection: Temperature controllers, limit controllers, and heating system for the oven. All these components have been previously inspected as used at the APS on multiple occasions. Location: Sector 12 |
Y |
|
92665 |
Nanosecond temperature-jump SAXS | Eric Landahl | DePaul University | 3/8/2012 | Y | Richard Heurich | 3/6/2012 @ 1000 | Mike Pape | laser class IV Location: 18-ID-D |
Y |
|
92305 |
In situ structure study of catalytic oxides during chemical processes by X-ray standing wave | Michael Bedzyk | Northwestern University | 2/29/2012 | Y | Sven Stoltz | 2/28/2012 @ 1400 | Clay White | power supply for Be-dome Location: 33-ID |
Y |
|
92307 |
ourth Generation USAXS Development for Combined XPCS/USAXS/SAXS Materials Microstructure Characterization | Andrew Allen | National Institute of Standards and Technology | 2/29/2012 | Y | Jan Ilavsky | 2/29/2012 @ 1300 | Clay White | 1. box of amplifiers (0-10 V DC) that has 110 VAC input Location: 434D |
Y |
|
92045 |
Multiframe Measurements with Synchrotron X-ray Laue Diffraction and Phase Contrast Imaging During Shock Wave Loading | Shengnian Luo | Los Alamos National Laboratory | 2/22/2012 | Y | Shengnian Luo | 2/22/2012 | Alex Deriy | High speed cameras | Y |
01-IDC-2012-G24756 92040 |
Simultaneous SAXS/WAXS on Deeply Undercool Metallic Liquids and Glasses | Matthew Kramer | Ames Laboratory | 2/17/2012 | Y | Ali Mashayekhi | 2/16/2012 | Bruno Fieramosca | Optical Furnace | Y |
|
91518 |
Advanced Block Polymer Based Materials | Tmothy Lodge | University of Minnesota | 2/9/2012 | Y | Grayce Theryo | 2/9/2012 @ 1000 | Bruno Fieramosca | Linkam DSC Polariscope Location: 5-ID-D |
Y |
|
91261 |
Next Generation Polychromatic Micro/Nano 3D X-Ray Diffraction Microscopy Instrumentation and Software | Gene Ice | Oak Ridge National Laboratory | 2/1/2012 | Y | Eliot Specht | 2/1/2012 @ 0800 | Lynette Jirik | Thermometer and motor controllers which were inspected by APS in Dec. 2011 and have not been modified Location: 34-ID-E |
Y |
All APS User electronic and electrical equipment must be inspected before use in an experiment. Please ask your beamline to make arrangements with one of the inspectors listed above.